PR0002 Joint Module CAN FD / CANopen Protocol Quick Guide
| Item | Information |
|---|---|
| Document No. | PR0002 |
| Revision | Rev. 1.0 |
| Applicable Products | Juxie Intelligent Joint Modules / Integrated Communication Modules |
| Applicable Firmware | 1.16.07 and above |
| Language | English |
| Last Updated | 2026-06-08 |
Disclaimer
Thank you for purchasing a Juxie Intelligent motor drive system. Before using the product, please read this guide, the product manual, and all relevant safety requirements carefully. Using the product constitutes acknowledgment and acceptance of the contents of this document. Users must strictly follow the manuals, product documentation, and applicable laws, regulations, policies, and standards when installing, commissioning, modifying, and operating the product, and assume full responsibility for their actions and any resulting consequences. Juxie Intelligent Drive Technology Co., Ltd. assumes no legal liability for losses caused by improper use, installation, or modification. No part of this document may be reproduced or reprinted in any form without prior permission. Juxie Intelligent Drive Technology Co., Ltd. reserves the right of final interpretation of this disclaimer.
1. Module Power-On Sequence
The typical startup sequence after powering on the Joint Module is as follows:
- Enters the Bootloader program and jumps to the Application after approximately
300 ms. - Application initialization takes approximately
2 s. - Once initialization completes, the device transmits a boot-up data frame with ID
0x700 + Dev_IDand payload00, while the power-on watchdog self-lock engages. - After enabling servo-on on the motor, wait
100 msbefore commanding motion to a new position.
Notes:
- The interval between watchdog data frames must be less than
500 ms; otherwise, the motor will self-lock. - Both Brake Release and brake engagement have a delay of approximately
100 ms.
2. CAN Bus Wiring Specifications
2.1 Signal Line Definitions
| Signal | Description |
|---|---|
CAN_H | CAN High data line; dominant level ~3.5 V, recessive level ~2.5 V |
CAN_L | CAN Low data line; dominant level ~1.5 V, recessive level ~2.5 V |
CAN_GND | Signal ground; establishes a common ground reference to improve common-mode noise immunity |
2.2 Termination Resistors
Termination resistors eliminate signal reflections at both ends of the bus to ensure signal integrity.
| Item | Specification |
|---|---|
| Quantity | One termination resistor must be installed at each of the two physical ends of the bus |
| Resistance | 120 ohm |
| Location | Install only on the two farthest end nodes; intermediate nodes on the bus must not have termination resistors installed |
| Connection | Connected in parallel between CAN_H and CAN_L |
| Verification | Measure resistance across the trunk lines with power off; a healthy network measures ~60 ohm total (two 120 ohm resistors in parallel) |

3. Protocol Overview
Juxie Intelligent Joint Modules support both CAN 2.0 and CAN FD communication, based on the CANopen 402 protocol (also known as CiA 402 or DS402), the device profile for drives and motion control within the CANopen protocol family.
3.1 Communication Configuration
Default CAN FD configuration:
- Standard frame (11-bit ID)
- Arbitration phase bit rate:
1 Mbps - Data phase bit rate:
5 Mbps - CAN FD Bit Rate Switch (BRS) enabled
3.2 Actuator ID
The actuator node ID range is 0x01 to 0x7F.
3.3 Object Dictionary
All parameters, process data, and functions are accessed via the Object Dictionary. Each object is addressed using a 16 bit index and an 8 bit sub-index.
3.4 Control Mode Mapping
Values written to 6060h are compatible with standard CiA 402 mode numbers. Upon receiving 6060h, the device translates it into the internal project mode. Reading 6061h, Byte 10 of fast-control feedback, and runtime logs report the translated internal project mode value.
6060h Write Value | Compatible Meaning | Internal Project Mode | Description |
|---|---|---|---|
0 | No mode | 0 | Does not enter a motion mode |
1 | Profile Position | 1 | Profile Position mode |
2 | Velocity | 2 | Mapped to internal Profile Velocity mode |
3 | Profile Velocity | 2 | Mapped to internal Profile Velocity mode |
4 | Profile Torque | 5 | Mapped to internal Current mode |
5 | Native Project Current Input | 5 | Current mode |
6 | Native Project MIT Input | 6 | MIT Impedance Control mode |
7 | Native Project Torque Sensor Closed-Loop Input | 7 | Supported only on models equipped with a Torque Sensor and torque loop |
8 | CSP (Cyclic Synchronous Position) | 3 | Mapped to internal CSP mode |
9 | CSV (Cyclic Synchronous Velocity) | 2 | Mapped to internal Profile Velocity mode |
10 | CST (Cyclic Synchronous Torque) | 5 | Mapped to internal Current mode |
Internal project mode values are defined as follows:
| Project Mode Value | Control Mode | Mode Name | Key Characteristics |
|---|---|---|---|
1 | PP / Profile Position | Profile Position Mode | Executes planned point-to-point motion using target position, profile velocity, and acceleration/deceleration |
2 | PV / Profile Velocity | Profile Velocity Mode | Executes velocity control using target velocity and profile acceleration/deceleration |
3 | CSP / Cyclic Synchronous Position | Cyclic Synchronous Position Mode | Host controller cyclically sends target positions |
4 | CSV / Cyclic Synchronous Velocity | Cyclic Synchronous Velocity Mode | Internal project velocity mode available via custom fast-control frames |
5 | Current | Current Mode | Directly commands target quadrature current Iq |
6 | MIT / Impedance | MIT Impedance Control Mode | Cyclically commands position, velocity, Stiffness, Damping, and Feedforward Torque |
7 | Torque Sensor | Torque Sensor Closed-Loop Mode | Performs closed-loop control on joint-side target torque |
The value written to 6060h and the internal project mode reported by the device may differ. For example, writing 6060h=10 enters the internal Current mode, so reading 6061h or checking fast-control feedback returns 5; writing 6060h=8 enters internal CSP mode, and feedback displays 3.
4. CAN FD / CANopen SDO Control Examples
4.1 SDO Frame Structure

When sent from the master to the slave, an SDO frame follows the common format below:
| CAN Frame Field | Length | Description |
|---|---|---|
StdID | 11 bit | 0x600 + Dev_ID |
DLC | - | 0x08 |
[0] | 8 bit | Command specifier (see SDO command specifier table below) |
[1]..[2] | 16 bit | Object Dictionary index, Little-Endian (low byte first) |
[3] | 8 bit | Sub-index |
[4]..[7] | 32 bit | Write payload, Little-Endian (low byte first, high byte last) |
SDO command specifiers:
| Command Code | Description | Direction |
|---|---|---|
2Fh | Write 1 byte to object | Master -> Slave |
2Bh | Write 2 bytes to object | Master -> Slave |
27h | Write 3 bytes to object | Master -> Slave |
23h | Write 4 bytes to object | Master -> Slave |
60h | Write confirmation response | Slave -> Master |
40h | Read data from object | Master -> Slave |
4Fh | Read response (1 byte) | Slave -> Master |
4Bh | Read response (2 bytes) | Slave -> Master |
47h | Read response (3 bytes) | Slave -> Master |
43h | Read response (4 bytes) | Slave -> Master |
4.2 Reading Motor Version Information
Version strings read back via SDO must be converted to ASCII characters.
| Information | ID | DLC | Data (HEX) |
|---|---|---|---|
| Manufacturer Name | 60X | 8 | 40 08 10 00 00 00 00 00 |
| Joint Model | 60X | 8 | 40 00 10 00 00 00 00 00 |
| Firmware Version | 60X | 8 | 40 0A 10 00 00 00 00 00 |
| Hardware Version | 60X | 8 | 40 09 10 00 00 00 00 00 |

4.3 Modifying Motor Node ID
Example: Set the motor ID to 5.
| ID | DLC | Data (HEX) | Description |
|---|---|---|---|
60x | 8 | 23 30 25 00 05 00 00 00 | Set motor ID to 5 |
4.4 Set Mechanical Zero Procedure
When performing zero-position calibration (Set Mechanical Zero), ensure proper state transitions as follows (note: standard calibration requires disabling the motor when saving):
- First enable the motor and move it to the desired mechanical zero position.
- Send the calibration command:
60x 23 31 25 00 01 00 00 00. - Read back the current actual position and verify that it reads
0, indicating successful zero calibration. - After disabling the motor and engaging the brake, send the calibration reset command as required by the firmware.
- Re-enable the motor; normal control can resume once Brake Release completes.
| ID | DLC | Data (HEX) | Description |
|---|---|---|---|
60x | 8 | 23 31 25 00 01 00 00 00 | Set Mechanical Zero |
4.5 Reading Motor Position
| ID | DLC | Data (HEX) | Description |
|---|---|---|---|
60x | 8 | 40 64 60 00 00 00 00 00 | Read actual motor position |
58x | 8 | 43 64 60 00 00 00 00 00 | Actual motor position response |
Position feedback is parsed in Little-Endian order (low byte first, high byte last). For example, FE 3F reconstructs to 0x3FFE (16382 in decimal); dividing by 182 gives approximately 90 deg.
| ID | Frame Format | Frame Type | DLC | CAN FD | Data |
|---|---|---|---|---|---|
0x601 | Standard | Data Frame | 8 | CAN FD | 43 64 60 00 00 00 00 00 |
0x581 | Standard | Data Frame | 8 | CAN FD | 43 64 60 00 FE 3F 00 00 |
4.6 Watchdog, Position Limits, and Heartbeat
Disabling the watchdog and position limit protections reduces on-site safety protection; use this only in controlled debugging scenarios where risks are clearly understood.
| Function | ID | DLC | Data (HEX) | Description |
|---|---|---|---|---|
| Disable watchdog and limit protection | 60x | 8 | 23 50 26 00 01 00 00 00 | Disables the 500 ms watchdog protection and position limit protection |
| Set heartbeat producer time | 60x | 8 | 2B 17 10 00 D0 07 00 00 | Sets heartbeat interval to 2000 ms; reverts to default after power cycle |
4.7 Software Position Limits and CAN Bit Rate
When setting positive and negative software limits, the motor must be disabled; save to Flash after configuration.
| Function | ID | DLC | Data (HEX) | Description |
|---|---|---|---|---|
| Set positive limit | 60x | 8 | 23 7D 60 02 30 7F 00 00 | Set positive position limit |
| Read negative limit | 60x | 8 | 40 7D 60 01 00 00 00 00 | Read sub-index 01 (min position limit) |
| Set negative limit | 60x | 8 | 23 7D 60 01 C8 80 FF FF | Set negative position limit |
| Read positive limit | 60x | 8 | 40 7D 60 02 00 00 00 00 | Read sub-index 02 (max position limit) |
0x2540:00 has been extended into a general CAN communication bit-rate configuration object, rather than representing only the CAN FD data phase baud rate. Written values are saved to BootPublic and take effect after a reset, reboot, or power cycle.
CAN communication rate values:
| Write Value | Communication Mode |
|---|---|
0 | Classic CAN 500K |
1 | Classic CAN 1M |
2 | CAN FD 1M/1M, BRS disabled |
3 | CAN FD 1M/2M, BRS enabled |
4 | CAN FD 1M/5M, BRS enabled |
| ID | DLC | Data (HEX) | Description |
|---|---|---|---|
60x | 8 | 40 40 25 00 00 00 00 00 | Read current CAN communication rate configuration |
60x | 8 | 23 40 25 00 04 00 00 00 | Set to CAN FD 1M/5M with BRS enabled |
For complete usage instructions and precautions, refer to TN0002 CANopen Communication Extended Features.
4.8 SDO Profile Position Mode Example
In position mode, the profile velocity refers to the reducer output shaft speed.
| Step | ID | DLC | Data (HEX) | Description |
|---|---|---|---|---|
| Ready to switch on | 601 | 8 | 2B 40 60 00 06 00 00 00 | Ready to switch on |
| Brake Release | 601 | 8 | 2B 40 60 00 07 00 00 00 | Release mechanical brake (Switched on) |
| Enable motor | 601 | 8 | 2B 40 60 00 0F 00 00 00 | Motor operation enabled |
| Set mode | 601 | 8 | 2F 60 60 00 01 00 00 00 | Set Profile Position mode |
| Set acceleration | 601 | 8 | 23 83 60 00 D0 07 00 00 | Acceleration 2000 RPM/s; motor-side range 0..10000 |
| Set deceleration | 601 | 8 | 23 84 60 00 D0 07 00 00 | Deceleration 2000 RPM/s; motor-side range 0..10000 |
| Set velocity | 601 | 8 | 23 81 60 00 0A 00 00 00 | Output shaft velocity 10 RPM, range 0..30 |
| Set target position | 601 | 8 | 23 7A 60 00 00 40 00 00 | Target position range -32767..32768 |
| Start absolute motion | 601 | 8 | 2B 40 60 00 4F 00 00 00 | Motor starts absolute positioning motion |
| Stop motion | 601 | 8 | 2B 40 60 00 0F 00 00 00 | Motor stops motion |
4.9 SDO Velocity Mode Example
Both velocity and acceleration in the velocity loop are defined at the motor shaft side.
| Step | ID | DLC | Data (HEX) | Description |
|---|---|---|---|---|
| Ready to switch on | 601 | 8 | 2B 40 60 00 06 00 00 00 | Ready to switch on |
| Brake Release | 601 | 8 | 2B 40 60 00 07 00 00 00 | Release mechanical brake |
| Enable motor | 601 | 8 | 2B 40 60 00 0F 00 00 00 | Motor operation enabled |
| Set mode | 601 | 8 | 2F 60 60 00 03 00 00 00 | Write 6060h=3 to enter Velocity mode; readback project mode is 2 |
| Set acceleration | 601 | 8 | 23 83 60 00 E8 03 00 00 | Acceleration 1000 RPM/s, range 0..10000 |
| Set deceleration | 601 | 8 | 23 84 60 00 E8 03 00 00 | Deceleration 1000 RPM/s, range 0..10000 |
| Set target velocity | 601 | 8 | 23 FF 60 00 F4 01 00 00 | Set velocity to 500 RPM |
4.10 SDO Current Mode & Torque Sensor Mode Example
It is recommended to keep the maximum current at its default value matching the motor's peak current rating.
| Step | ID | DLC | Data (HEX) | Description |
|---|---|---|---|---|
| Ready to switch on | 601 | 8 | 2B 40 60 00 06 00 00 00 | Ready to switch on |
| Brake Release | 601 | 8 | 2B 40 60 00 07 00 00 00 | Release mechanical brake |
| Enable motor | 601 | 8 | 2B 40 60 00 0F 00 00 00 | Motor operation enabled |
| Set mode | 601 | 8 | 2F 60 60 00 0A 00 00 00 | Write 6060h=10 (compatible CST input) to enter project Current mode; readback project mode is 5 |
| Set target current | 601 | 8 | 2B 71 60 00 F4 01 00 00 | Set target current 500 mA; refer to motor specifications for valid range |
You may also write 6060h=5 to enter the native project Current mode directly. If the master uses standard CiA 402 CST numbering, continue using 6060h=10.
Torque Sensor Closed-Loop Mode applies only to models configured with a Torque Sensor and torque loop. This mode uses the native project input 6060h=7, with the target torque written via 6071h in units of 0.1 Nm:
| Step | ID | DLC | Data (HEX) | Description |
|---|---|---|---|---|
| Ready to switch on | 601 | 8 | 2B 40 60 00 06 00 00 00 | Ready to switch on |
| Brake Release | 601 | 8 | 2B 40 60 00 07 00 00 00 | Release mechanical brake |
| Enable motor | 601 | 8 | 2B 40 60 00 0F 00 00 00 | Motor operation enabled |
| Set mode | 601 | 8 | 2F 60 60 00 07 00 00 00 | Write 6060h=7 to enter Torque Sensor Closed-Loop Mode |
| Set target torque | 601 | 8 | 2B 71 60 00 0A 00 00 00 | Raw value 10, corresponding to 1.0 Nm joint-side target torque |
4.11 PI Gains and Saving to Flash
| Parameter | ID | DLC | Data (HEX) | Description |
|---|---|---|---|---|
| Current Loop P | 601 | 8 | 23 32 25 00 00 00 00 00 | Set motor current loop P |
| Current Loop I | 601 | 8 | 23 33 25 00 00 00 00 00 | Set motor current loop I |
| Velocity Loop P | 601 | 8 | 23 34 25 00 00 00 00 00 | Set motor velocity loop P |
| Velocity Loop I | 601 | 8 | 23 35 25 00 00 00 00 00 | Set motor velocity loop I |
| Position Loop P | 601 | 8 | 23 36 25 00 00 00 00 00 | Set motor position loop P |
| Position Loop I | 601 | 8 | 23 37 25 00 00 00 00 00 | Set motor position loop I |
Save written PI gains and maximum current to Flash:
| ID | DLC | Data (HEX) | Description |
|---|---|---|---|
601 | 8 | 23 39 25 00 01 00 00 00 | Save to Flash |
Read PI parameters:
| Parameter | Data (HEX) |
|---|---|
| Read motor current loop P | 40 32 25 00 00 00 00 00 |
| Read motor current loop I | 40 33 25 00 00 00 00 00 |
| Read motor velocity loop P | 40 34 25 00 00 00 00 00 |
| Read motor velocity loop I | 40 35 25 00 00 00 00 00 |
| Read motor position loop P | 40 36 25 00 00 00 00 00 |
| Read motor position loop I | 40 37 25 00 00 00 00 00 |
| Read motor max current | 40 38 25 00 00 00 00 00 |
4.12 SDO Status & Feedback Reading Examples
| ID | DLC | Data (HEX) | Description | Parsing |
|---|---|---|---|---|
601 | 8 | 40 78 60 00 00 00 00 00 | Read actual motor current | - |
581 | 8 | 4B 78 60 00 45 01 00 00 | Actual motor current response | 0x0145 = 325 decimal, unit: mA |
601 | 8 | 40 64 60 00 00 00 00 00 | Read actual motor position | - |
581 | 8 | 43 64 60 00 FE 3F 00 00 | Actual motor position response | 0x3FFE = 16382; divided by 182 ~= 90 deg; 65536 counts/rev corresponds to -180..180 deg |
601 | 8 | 40 6C 60 00 00 00 00 00 | Read actual motor velocity | - |
581 | 8 | 43 6C 60 00 F9 01 00 00 | Actual motor velocity response | 0x01F9 converts to 50.5 RPM |
601 | 8 | 40 3F 60 00 00 00 00 00 | Read motor fault code | - |
581 | 8 | 4B 3F 60 00 00 00 00 00 | Motor fault code response | See Troubleshooting section for fault code definitions |
601 | 8 | 40 41 60 00 00 00 00 00 | Read motor statusword | - |
581 | 8 | 4B 41 60 00 00 00 00 00 | Motor statusword response | 0x0021: Ready to switch on; 0x0023: Brake Release (Switched on); 0x0027: Operation enabled; 0x0008: Fault state |
601 | 8 | 40 62 26 00 00 00 00 00 | Read MOSFET temperature sensor | - |
581 | 8 | 43 62 26 00 18 01 00 00 | Temperature sensor response | 0x0118 = 280 decimal, i.e., 28.0 degC |
601 | 8 | 40 63 26 00 00 00 00 00 | Read motor winding temperature sensor | - |
581 | 8 | 43 63 26 00 18 01 00 00 | Temperature sensor response | 0x0118 = 280 decimal, i.e., 28.0 degC |
0x603F returns legacy manufacturer-compatible fault codes. For V2.0 and later firmware, to read the V2.0 diagnostic error codes, refer to FC0001 V2.0 Error Codes & SDO Reading and read 0x4500 to obtain the lower 16 bits of the full V2.0 diagnostic ID.
5. CAN FD Custom PDO Control Examples
5.1 Single-Actuator Control Frame
Sent from the host controller to an individual actuator:
| Field | Length | Description |
|---|---|---|
StdID | 11 bit | 0x100 + Dev_ID |
DLC | - | 7 |
[0].Bit[7] | 1 bit | Enable control: 0 = Disable, 1 = Enable |
[0].Bit[6] | 1 bit | Brake control: 0 = Brake engaged, 1 = Brake Release |
[0].Bit[5] | 1 bit | Clear fault control: 0 = Default, 1 = Fault reset |
[0].Bit[4:1] | 4 bit | Project mode value: 0x01 Profile Position, 0x02 Profile Velocity, 0x03 CSP, 0x04 CSV, 0x05 Current, 0x06 MIT, 0x07 Torque Sensor Closed-Loop |
[0].Bit[0] | - | Reserved |
[1]..[2] | 16 bit | Target Parameter 1 (Big-Endian). Position mode: output-side target position (-32768..32767 -> -180..180 deg); Velocity mode: motor-side target velocity (RPM); Current mode: target Iq current (mA); Torque Sensor Closed-Loop mode: joint-side target torque (0.1 Nm) |
[3]..[4] | 16 bit | Target Parameter 2 (Big-Endian). Profile Position and Profile Velocity modes: profile acceleration/deceleration, range 0..20000, unit RPM/s |
[5]..[6] | 16 bit | Target Feedforward Parameter (Big-Endian). Position mode: output-side profile velocity; reserved in other modes |
5.2 Single-Axis Control Frame Examples
The examples below assume motor Dev_ID = 1.
| No. | ID | Protocol | DLC | Description | Data |
|---|---|---|---|---|---|
| 0 | 0x101 | CAN FD | 7 | PP mode move to 0 cnt, accel/decel 2000, speed 5 | C2 00 00 07 D0 00 05 |
| 1 | 0x101 | CAN FD | 7 | PP mode move to 16384 cnt, accel/decel 1000, speed 8 | C2 40 00 03 E8 00 08 |
| 2 | 0x101 | CAN FD | 7 | PP mode move to -16384 cnt, accel/decel 1000, speed 8 | C2 C0 00 03 E8 00 08 |
| 3 | 0x101 | CAN FD | 7 | Velocity mode, speed 500, accel/decel 1000 | C4 01 F4 03 E8 00 00 |
| 4 | 0x101 | CAN FD | 7 | Velocity mode, speed -500, accel/decel 1000 | C4 FE 0C 03 E8 00 00 |
| 5 | 0x101 | CAN FD | 7 | Current mode, current 1000 | CA 03 E8 00 00 00 00 |
| 6 | 0x101 | CAN FD | 7 | Current mode, current -1000 | CA FC 18 00 00 00 00 |
| 7 | 0x101 | CAN FD | 7 | CSP mode move to 50 cnt | C6 00 32 00 00 00 00 |
| 8 | 0x101 | CAN FD | 7 | CSP mode move to 100 cnt | C6 00 64 00 00 00 00 |
| 9 | 0x101 | CAN FD | 7 | Torque Sensor Closed-Loop mode, target torque 1.0 Nm | CE 00 0A 00 00 00 00 |
The mode field in custom fast-control frames uses the internal project mode value directly without applying 6060h compatibility mapping. MIT Impedance Control uses dedicated single-axis (0x110 + Dev_ID) or 64-byte multi-axis (0x210) fast-control frames; see TN0001 CAN FD MIT Mode and Force Control Tuning Guide for details.
Simple feedback example:
| ID | Frame Format | Frame Type | DLC | CAN FD | Data |
|---|---|---|---|---|---|
0x101 | Standard | Data Frame | 7 | CAN FD | C2 00 00 07 D0 00 05 |
0x301 | Standard | Data Frame | 12 | CAN FD | FF FE 00 00 FF E2 00 00 01 04 01 D0 |
0x081 | Standard | Data Frame | 8 | CAN FD | 02 00 00 00 00 00 00 00 |
5.3 Multi-Actuator Control Frame
The multi-actuator control frame broadcasts commands to control up to 8 motors simultaneously.
| Field | Length | Description |
|---|---|---|
StdID | 11 bit | 0x200 |
DLC | - | 64 |
[0]..[6] | 7 bytes | Control command sub-packet 1 |
[7]..[13] | 7 bytes | Control command sub-packet 2 |
[14]..[20] | 7 bytes | Control command sub-packet 3 |
[21]..[27] | 7 bytes | Control command sub-packet 4 |
[28]..[34] | 7 bytes | Control command sub-packet 5 |
[35]..[41] | 7 bytes | Control command sub-packet 6 |
[42]..[48] | 7 bytes | Control command sub-packet 7 |
[49]..[55] | 7 bytes | Control command sub-packet 8 |
[56]..[63] | 8 bytes | Target actuator ID (Dev_ID) for each corresponding sub-packet |
Each 7-byte control sub-packet has the exact same layout as the single-actuator control frame. Pad unused sub-packets and ID slots with 00.
7-axis control example:
0x200:
D0 16 E5 00 00 00 00 D0 2D 15 00 00 00 00 D0 17 EA 00 00 00 00
D0 FD 65 00 00 00 00 D0 E1 07 00 00 00 00 D0 F4 E9 00 00 00 00
D0 08 C8 00 00 00 00 00 00 00 00 00 00 00 01 02 03 04 05 06 07
00
0x301: 16 E3 00 00 F5 2D 01 98 01 DC 70 00
0x302: 2D 17 00 00 F7 B0 01 B5 01 DE 70 00
0x303: 18 41 FF A0 F4 49 01 BE 01 C8 70 00
0x304: FD 78 FF E8 04 50 01 AB 01 E0 70 00
0x305: E2 80 FE 8B FA CD 01 BE 01 F4 70 00
0x306: F5 51 FF A6 FF 2F 01 CC 01 E4 70 00
0x307: 08 B2 00 01 FF C3 01 C2 01 E2 70 00
5.4 MIT Impedance Control Entry Points
MIT mode supports both a fixed PDO4/MIT channel under full CANopen and custom single-axis / multi-axis fast-control entry points. All three entry points share the same 8-byte 5-tuple MIT bit-packing scheme:
| Entry Point | CAN ID | Payload Bytes | Description |
|---|---|---|---|
| PDO4/MIT Fixed Channel | 0x500 + Dev_ID | 8 | Used in full CANopen mode; payload is a fixed 8B MIT packet. Does not include a control byte—requires prior entry into Operation enabled + MIT mode, and is not parsed via OD 1603h mapping |
| MIT Single-Axis Fast Control | 0x110 + Dev_ID | 9 (padded to 12B CAN FD) | Byte0 carries enable, Brake Release, fault clear, and internal mode bits; Byte1..8 match the 8B PDO4/MIT payload |
| MIT Multi-Axis Fast Control | 0x210 | 64 | Carries up to six 9B MIT sub-frames using the same bit-packing scheme as single-axis fast control |
For the complete MIT workflow, 8B bit-packing C code, and ready-to-send frame examples, refer to TN0001 CAN FD MIT Mode and Force Control Tuning Guide.
6. Actuator Feedback Frame
Actuator feedback frames can be triggered in three ways:
- Host controller sends a SYNC frame with ID
0x80. - Triggered automatically upon receiving a multi-actuator control frame.
- Triggered automatically upon receiving a single-axis control frame.
Sent from the actuator to the host controller:
| Field | Length | Description |
|---|---|---|
StdID | 11 bit | 0x300 + Dev_ID |
DLC | - | 12 bytes |
[0]..[1] | 16 bit | Load-side actual position (Byte[0] high byte, Byte[1] low byte), range -32768..32767 -> -180..180 deg |
[2]..[3] | 16 bit | Motor-side actual velocity (int16, Big-Endian), unit: RPM |
[4]..[5] | 16 bit | Actual current Iq (int16, Big-Endian), unit: mA |
[6]..[7] | 16 bit | Error code (Big-Endian), see Troubleshooting fault table |
[8]..[9] | 16 bit | Motor winding temperature (int16, Big-Endian), unit: 0.1 degC |
[10] | 8 bit | Project mode feedback: 0x01 Profile Position, 0x02 Profile Velocity, 0x03 CSP, 0x04 CSV, 0x05 Current, 0x06 MIT, 0x07 Torque Sensor Closed-Loop |
[11].Bit[7] | 1 bit | Enable state: 0 = Disabled, 1 = Enabled |
[11].Bit[6] | 1 bit | Brake state: 0 = Brake engaged, 1 = Brake Release |
[11].Bit[5] | 1 bit | Fault state: 0 = Normal, 1 = Fault active |
[11].Bit[4] | 1 bit | Position reached state: 0 = In motion, 1 = Target reached |
[11].Bit[3:0] | - | Reserved |
Feedback parsing example:
| Direction | ID | Frame Format | Frame Type | Bytes | CAN FD | Data |
|---|---|---|---|---|---|---|
| Tx | 0x101 | Standard | Data Frame | 7 | CAN FD | C2 00 00 07 D0 00 05 |
| Rx | 0x301 | Standard | Data Frame | 12 | CAN FD | 09 E1 FD E5 FF 51 00 00 00 F0 01 C0 |
| Data | Decoded Value |
|---|---|
09 E1 | 13 deg |
FD E5 | -539 RPM |
FF 51 | -175 mA |
00 00 | No fault |
00 F0 | 24 degC |
01 | Profile Position mode |
C0 | 1100 0000 binary: Enabled, Brake Release, Normal (no fault), In motion |
7. Standard CANopen PDO Configuration
Standard CANopen PDOs do not come with pre-configured complete mappings and should be configured by the user according to application requirements. Because code snippets converted from the legacy Word manual contained OCR formatting shifts, the configuration procedure is presented below as an exact CAN frame sequence.
Typical PDO mapping sequence (for Node ID 1):
| ID | Frame Type | Frame Format | Length | Data | Description |
|---|---|---|---|---|---|
0x0701 | Data Frame | Standard | 0x01 | 00 | Power-on boot-up message |
0x0000 | Data Frame | Standard | 0x02 | 81 01 | Reset node |
0x0601 | Data Frame | Standard | 0x08 | 2B 17 10 00 C8 00 00 00 | Configure heartbeat producer time (200 ms) |
0x0581 | Data Frame | Standard | 0x08 | 60 17 10 00 00 00 00 00 | Response |
0x0601 | Data Frame | Standard | 0x08 | 23 00 18 01 81 01 00 80 | Disable txPDO1 |
0x0581 | Data Frame | Standard | 0x08 | 60 00 18 01 00 00 00 00 | Disable txPDO1 response |
0x0601 | Data Frame | Standard | 0x08 | 23 01 18 01 81 02 00 80 | Disable txPDO2 |
0x0581 | Data Frame | Standard | 0x08 | 60 01 18 01 00 00 00 00 | Disable txPDO2 response |
0x0601 | Data Frame | Standard | 0x08 | 23 02 18 01 81 03 00 80 | Disable txPDO3 |
0x0581 | Data Frame | Standard | 0x08 | 60 02 18 01 00 00 00 00 | Disable txPDO3 response |
0x0601 | Data Frame | Standard | 0x08 | 23 03 18 01 81 04 00 80 | Disable txPDO4 |
0x0581 | Data Frame | Standard | 0x08 | 60 03 18 01 00 00 00 00 | Disable txPDO4 response |
0x0601 | Data Frame | Standard | 0x08 | 23 00 14 01 01 02 00 80 | Disable rxPDO1 |
0x0581 | Data Frame | Standard | 0x08 | 60 00 14 01 00 00 00 00 | Disable rxPDO1 response |
0x0601 | Data Frame | Standard | 0x08 | 23 01 14 01 01 03 00 80 | Disable rxPDO2 |
0x0581 | Data Frame | Standard | 0x08 | 60 01 14 01 00 00 00 00 | Disable rxPDO2 response |
0x0601 | Data Frame | Standard | 0x08 | 23 02 14 01 01 04 00 80 | Disable rxPDO3 |
0x0581 | Data Frame | Standard | 0x08 | 60 02 14 01 00 00 00 00 | Disable rxPDO3 response |
0x0601 | Data Frame | Standard | 0x08 | 23 03 14 01 01 05 00 80 | Disable rxPDO4 |
0x0581 | Data Frame | Standard | 0x08 | 60 03 14 01 00 00 00 00 | Disable rxPDO4 response |
0x0601 | Data Frame | Standard | 0x08 | 2F 00 18 02 01 00 00 00 | Set TPDO1 transmission type (every SYNC) |
0x0581 | Data Frame | Standard | 0x08 | 60 00 18 02 00 00 00 00 | Response |
0x0601 | Data Frame | Standard | 0x08 | 2F 00 1A 00 00 00 00 00 | Clear txPDO1 mapping count |
0x0581 | Data Frame | Standard | 0x08 | 60 00 1A 00 00 00 00 00 | Response |
0x0601 | Data Frame | Standard | 0x08 | 23 00 1A 01 10 00 41 60 | Map 6041 Statusword (16 bit) |
0x0581 | Data Frame | Standard | 0x08 | 60 00 1A 01 00 00 00 00 | Response |
0x0601 | Data Frame | Standard | 0x08 | 23 00 1A 02 10 00 78 60 | Map 6078 Actual Current (16 bit) |
0x0581 | Data Frame | Standard | 0x08 | 60 00 1A 02 00 00 00 00 | Response |
0x0601 | Data Frame | Standard | 0x08 | 23 00 1A 03 20 00 64 60 | Map 6064 Actual Position (32 bit) |
0x0581 | Data Frame | Standard | 0x08 | 60 00 1A 03 00 00 00 00 | Response |
0x0601 | Data Frame | Standard | 0x08 | 2F 00 1A 00 03 00 00 00 | Enable 3 mapped objects in txPDO1 |
0x0581 | Data Frame | Standard | 0x08 | 60 00 1A 00 00 00 00 00 | Response |
0x0601 | Data Frame | Standard | 0x08 | 23 00 18 01 81 01 00 00 | Enable txPDO1 with COB-ID 0x181 |
0x0581 | Data Frame | Standard | 0x08 | 60 00 18 01 00 00 00 00 | Response |
0x0601 | Data Frame | Standard | 0x08 | 2F 00 14 02 01 00 00 00 | Set RPDO1 transmission type (synchronous) |
0x0581 | Data Frame | Standard | 0x08 | 60 00 14 02 00 00 00 00 | Response |
0x0601 | Data Frame | Standard | 0x08 | 2F 00 16 00 00 00 00 00 | Clear rxPDO1 mapping count |
0x0581 | Data Frame | Standard | 0x08 | 60 00 16 01 00 00 00 00 | Response |
0x0601 | Data Frame | Standard | 0x08 | 23 00 16 01 10 00 40 60 | Map 6040 Controlword (16 bit) |
0x0581 | Data Frame | Standard | 0x08 | 60 00 16 01 00 00 00 00 | Response |
0x0601 | Data Frame | Standard | 0x08 | 23 00 16 02 10 00 71 60 | Map 6071 Target Current / Torque (16 bit) |
0x0581 | Data Frame | Standard | 0x08 | 60 00 16 02 00 00 00 00 | Response |
0x0601 | Data Frame | Standard | 0x08 | 23 00 16 03 20 00 7A 60 | Map 607A Target Position (32 bit) |
0x0581 | Data Frame | Standard | 0x08 | 60 00 16 03 00 00 00 00 | Response |
0x0601 | Data Frame | Standard | 0x08 | 2F 00 16 00 03 00 00 00 | Enable 3 mapped objects in rxPDO1 |
0x0581 | Data Frame | Standard | 0x08 | 60 00 16 00 00 00 00 00 | Response |
0x0601 | Data Frame | Standard | 0x08 | 23 00 14 01 01 02 00 00 | Enable rxPDO1 with COB-ID 0x201 |
0x0581 | Data Frame | Standard | 0x08 | 60 00 14 01 00 00 00 00 | Response |
0x0601 | Data Frame | Standard | 0x08 | 2F 60 60 00 08 00 00 00 | Write 6060h=8 to select CSP; readback project mode is 3 |
0x0581 | Data Frame | Standard | 0x08 | 60 60 60 00 00 00 00 00 | Response |
0x0701 | Data Frame | Standard | 0x01 | 7F | Node heartbeat (Pre-Operational) |
0x0000 | Data Frame | Standard | 0x02 | 01 00 | NMT Start all nodes (enter Operational) |
0x0080 | Data Frame | Standard | 0x00 | - | SYNC frame |
8. Encoder Specifications
8.1 Encoder Resolution & Single-Turn Position Feedback
The Joint Module achieves full closed-loop control using dual single-turn absolute encoders:
- Motor-side encoder resolution:
14 bit, i.e.,16384 cnt/rev. - Load-side (output) encoder resolution:
16 bit, i.e.,65536counts per revolution, raw feedback range0..65535.
When the output shaft crosses the zero mark, the raw single-turn reading wraps around: 65535 -> 0 in the positive direction and 0 -> 65535 in the negative direction. Full closed-loop host algorithms must compensate for this zero-crossing wraparound to avoid transient disturbances.
The 16 bit absolute encoder has an angular error within +/-0.5 deg and repeatability within +/-0.05 deg.
Formula for converting single-turn angle theta to position counts:
position = theta / 360 deg * 65536
For example, when theta = 20 deg:
position = 20 / 360 * 65536 ~= 3641
Equivalent incremental encoder line count: 4096.
8.2 Position Feedback Diagram

9. Module Connector Pinout
Because connector tables converted from the legacy Word document contained duplicated OCR entries, only verified module models, connector part numbers, and pin assignments are listed below. Always verify actual wiring against product silkscreen markings, mechanical drawings, or the datasheet shipped with your hardware.
| Model | Power Connector | Power Pinout | Communication Connector | Communication Pinout |
|---|---|---|---|---|
R120 / R120MAX | XT30AW-M.G.Y, AMASS | 1: G, 2: VIN | X1251WVS-03HF-LPSW, XKB-Connection | 1: H, 2: L, 3: G |
R102 | XT30AW-M.G.Y, AMASS | 1: G, 2: VIN | X1251WVS-03HF-LPSW, XKB-Connection | 1: H, 2: L, 3: G |
R83 | XT30AW-M.G.Y, AMASS | 1: G, 2: VIN | B03B-XNISK-A-1(LF)(SN), JST | 1: H, 2: L, 3: G |
R68 | XT30AW-M.G.Y, AMASS | 1: G, 2: VIN | X1251WVS-03HF-LPSW, XKB-Connection | 1: H, 2: L, 3: G |
R58 | DL15006-2AB, Delilai (德利来) | 1: G, 2: 24+ | DL12503-3AB, Delilai (德利来) | 1: G, 2: L, 3: H |
R48 | B02B-XNISK-A-1(LF)(SN), JST | 1: G, 2: VIN | B03B-ZESK-1D(LF)(SN), JST | 1: G, 2: L, 3: H |
R48-101-DNF | B02B-XNISK-A-1(LF)(SN), JST | 1: G, 2: VIN | B03B-ZESK-1D(LF)(SN), JST | 1: G, 2: L, 3: H |
R83-101-FBN | XT30AW-M.G.Y, AMASS | 1: G, 2: VIN | B03B-XNISK-A-1(LF)(SN), JST | 1: H, 2: L, 3: G |
R80-50-13NSFN | XT30U-M Female, AMASS | 1: G, 2: 24+ | DL12503-3AB, Delilai (德利来) | 1: G, 2: L, 3: H |
R68-101-lite | XT30AW-M.G.Y, AMASS | 1: G, 2: VIN | X1251WVS-03HF-LPSW, XKB-Connection | 1: H, 2: L, 3: G |
R48-101-lite | DL15006-2AB, Delilai (德利来) | Refer to datasheet | DL12503-3AB / HC-0.8-6PLT | HC-0.8-6PLT: 1: G, 2: L, 3: H, 4: G, 5: L, 6: H |
10. Troubleshooting & Fault Codes
When the motor reports an abnormal alarm, refer to the fault codes below.
The table below lists legacy compatibility fault codes applicable to existing parsing workflows on corresponding products and firmware. Firmware supporting V2.0 diagnostic IDs uses 0xDDSS encoding; see FC0001 V2.0 Error Codes & SDO Reading for reading methods, and FC0002 Joint Module Fault Alarm & Protection Logic Guide for protection actions and troubleshooting procedures.
| Fault Name | Trigger Condition | Protection Level | Fault Clearing Method | Fault Code | Notes |
|---|---|---|---|---|---|
| Undervoltage | Bus voltage < 40 V | Fast Protection | Power cycle to clear | 0x0002 | Hardware undervoltage threshold is 35 V |
| Overvoltage | Bus voltage > 72 V | General Protection | Power cycle to clear | 0x0001 | - |
| Overtemperature | Motor winding NTC > 95 degC for 100 ms, or drive NTC > 100 degC for 100 ms; temperature rise-rate protection active above 80 degC | General Protection | Clear via command after cooling below 85 degC | 0x0004 | - |
| Motor Stall | Motor Iq reaches or exceeds configured max current for 2 s | Current-Limit Protection | Power cycle to clear | 0x0008 | - |
| Overload | Motor Iq current integral exceeds configured threshold | General Protection | Power cycle to clear | 0x0010 | - |
| Excessive Velocity Tracking Error | Error between desired and actual velocity > 320 RPM for 20 ms (R120 / R120MAX only; 200 RPM threshold on other modules) | Fast Protection | Power cycle to clear | 0x0020 | May trigger under sudden load impact; gradual overload may trigger stall or velocity tracking error |
| Positive Limit Protection | Limit photo-sensor triggered or software positive angle limit exceeded while target velocity is in the positive limit direction. Default software positive limit: 32767 | Fast Protection | Clear via command; motion allowed in opposite direction | 0x0040 | - |
| Negative Limit Protection | Limit photo-sensor triggered or software negative angle limit exceeded while target velocity is in the negative limit direction. Default software negative limit: -32767 | Fast Protection | Clear via command; motion allowed in opposite direction | 0x0080 | - |
| Output Encoder Abnormality | Compares velocity calculated from output encoder against motor-side velocity; triggers when output encoder velocity is 0 while motor side is 100 RPM for 20 ms (and vice versa) | Fast Protection | Power cycle to clear | 0x0100 | - |
| Excessive Position Jump | Target position increment in CSP mode > 100 cnt per 1 ms cycle | Servo holds current position | Clear via command | 0x0200 | - |
| Current Sensing Fault | Current sensing zero-offset out of valid range during initialization | Fast Protection | Power cycle to clear | 0x0400 | - |
| Excessive Current Tracking Error | Error between target and feedback current > 10 A for 20 ms (threshold scaled by rated current) | Fast Protection | Power cycle to clear | 0x0800 | May be caused by phase loss or abnormal motor parameters |
| Excessive Position Tracking Error | Error between desired and actual position > 2000 cnt for 20 ms | Fast Protection | Power cycle to clear | 0x1000 | - |
Protection level descriptions:
| Protection Level | Protection Action Sequence |
|---|---|
| General Protection | Decelerate speed below threshold; engage brake; wait 100 ms; turn off PWM |
| Fast Protection | Turn off PWM immediately; engage brake |
| Current-Limit Protection | Clamp current to 50% of max current; engage brake; wait 100 ms; turn off PWM |