PR0002 Joint Module CAN FD / CANopen Protocol Quick Guide

ItemInformation
Document No.PR0002
RevisionRev. 1.0
Applicable ProductsJuxie Intelligent Joint Modules / Integrated Communication Modules
Applicable Firmware1.16.07 and above
LanguageEnglish
Last Updated2026-06-08

Disclaimer​

Thank you for purchasing a Juxie Intelligent motor drive system. Before using the product, please read this guide, the product manual, and all relevant safety requirements carefully. Using the product constitutes acknowledgment and acceptance of the contents of this document. Users must strictly follow the manuals, product documentation, and applicable laws, regulations, policies, and standards when installing, commissioning, modifying, and operating the product, and assume full responsibility for their actions and any resulting consequences. Juxie Intelligent Drive Technology Co., Ltd. assumes no legal liability for losses caused by improper use, installation, or modification. No part of this document may be reproduced or reprinted in any form without prior permission. Juxie Intelligent Drive Technology Co., Ltd. reserves the right of final interpretation of this disclaimer.

1. Module Power-On Sequence​

The typical startup sequence after powering on the Joint Module is as follows:

  1. Enters the Bootloader program and jumps to the Application after approximately 300 ms.
  2. Application initialization takes approximately 2 s.
  3. Once initialization completes, the device transmits a boot-up data frame with ID 0x700 + Dev_ID and payload 00, while the power-on watchdog self-lock engages.
  4. After enabling servo-on on the motor, wait 100 ms before commanding motion to a new position.

Notes:

  • The interval between watchdog data frames must be less than 500 ms; otherwise, the motor will self-lock.
  • Both Brake Release and brake engagement have a delay of approximately 100 ms.

2. CAN Bus Wiring Specifications​

2.1 Signal Line Definitions​

SignalDescription
CAN_HCAN High data line; dominant level ~3.5 V, recessive level ~2.5 V
CAN_LCAN Low data line; dominant level ~1.5 V, recessive level ~2.5 V
CAN_GNDSignal ground; establishes a common ground reference to improve common-mode noise immunity

2.2 Termination Resistors​

Termination resistors eliminate signal reflections at both ends of the bus to ensure signal integrity.

ItemSpecification
QuantityOne termination resistor must be installed at each of the two physical ends of the bus
Resistance120 ohm
LocationInstall only on the two farthest end nodes; intermediate nodes on the bus must not have termination resistors installed
ConnectionConnected in parallel between CAN_H and CAN_L
VerificationMeasure resistance across the trunk lines with power off; a healthy network measures ~60 ohm total (two 120 ohm resistors in parallel)

CAN Termination Resistor Diagram

3. Protocol Overview​

Juxie Intelligent Joint Modules support both CAN 2.0 and CAN FD communication, based on the CANopen 402 protocol (also known as CiA 402 or DS402), the device profile for drives and motion control within the CANopen protocol family.

3.1 Communication Configuration​

Default CAN FD configuration:

  • Standard frame (11-bit ID)
  • Arbitration phase bit rate: 1 Mbps
  • Data phase bit rate: 5 Mbps
  • CAN FD Bit Rate Switch (BRS) enabled

3.2 Actuator ID​

The actuator node ID range is 0x01 to 0x7F.

3.3 Object Dictionary​

All parameters, process data, and functions are accessed via the Object Dictionary. Each object is addressed using a 16 bit index and an 8 bit sub-index.

3.4 Control Mode Mapping​

Values written to 6060h are compatible with standard CiA 402 mode numbers. Upon receiving 6060h, the device translates it into the internal project mode. Reading 6061h, Byte 10 of fast-control feedback, and runtime logs report the translated internal project mode value.

6060h Write ValueCompatible MeaningInternal Project ModeDescription
0No mode0Does not enter a motion mode
1Profile Position1Profile Position mode
2Velocity2Mapped to internal Profile Velocity mode
3Profile Velocity2Mapped to internal Profile Velocity mode
4Profile Torque5Mapped to internal Current mode
5Native Project Current Input5Current mode
6Native Project MIT Input6MIT Impedance Control mode
7Native Project Torque Sensor Closed-Loop Input7Supported only on models equipped with a Torque Sensor and torque loop
8CSP (Cyclic Synchronous Position)3Mapped to internal CSP mode
9CSV (Cyclic Synchronous Velocity)2Mapped to internal Profile Velocity mode
10CST (Cyclic Synchronous Torque)5Mapped to internal Current mode

Internal project mode values are defined as follows:

Project Mode ValueControl ModeMode NameKey Characteristics
1PP / Profile PositionProfile Position ModeExecutes planned point-to-point motion using target position, profile velocity, and acceleration/deceleration
2PV / Profile VelocityProfile Velocity ModeExecutes velocity control using target velocity and profile acceleration/deceleration
3CSP / Cyclic Synchronous PositionCyclic Synchronous Position ModeHost controller cyclically sends target positions
4CSV / Cyclic Synchronous VelocityCyclic Synchronous Velocity ModeInternal project velocity mode available via custom fast-control frames
5CurrentCurrent ModeDirectly commands target quadrature current Iq
6MIT / ImpedanceMIT Impedance Control ModeCyclically commands position, velocity, Stiffness, Damping, and Feedforward Torque
7Torque SensorTorque Sensor Closed-Loop ModePerforms closed-loop control on joint-side target torque
important

The value written to 6060h and the internal project mode reported by the device may differ. For example, writing 6060h=10 enters the internal Current mode, so reading 6061h or checking fast-control feedback returns 5; writing 6060h=8 enters internal CSP mode, and feedback displays 3.

4. CAN FD / CANopen SDO Control Examples​

4.1 SDO Frame Structure​

SDO Frame Format Diagram

When sent from the master to the slave, an SDO frame follows the common format below:

CAN Frame FieldLengthDescription
StdID11 bit0x600 + Dev_ID
DLC-0x08
[0]8 bitCommand specifier (see SDO command specifier table below)
[1]..[2]16 bitObject Dictionary index, Little-Endian (low byte first)
[3]8 bitSub-index
[4]..[7]32 bitWrite payload, Little-Endian (low byte first, high byte last)

SDO command specifiers:

Command CodeDescriptionDirection
2FhWrite 1 byte to objectMaster -> Slave
2BhWrite 2 bytes to objectMaster -> Slave
27hWrite 3 bytes to objectMaster -> Slave
23hWrite 4 bytes to objectMaster -> Slave
60hWrite confirmation responseSlave -> Master
40hRead data from objectMaster -> Slave
4FhRead response (1 byte)Slave -> Master
4BhRead response (2 bytes)Slave -> Master
47hRead response (3 bytes)Slave -> Master
43hRead response (4 bytes)Slave -> Master

4.2 Reading Motor Version Information​

Version strings read back via SDO must be converted to ASCII characters.

InformationIDDLCData (HEX)
Manufacturer Name60X840 08 10 00 00 00 00 00
Joint Model60X840 00 10 00 00 00 00 00
Firmware Version60X840 0A 10 00 00 00 00 00
Hardware Version60X840 09 10 00 00 00 00 00

Version String ASCII Conversion Example

4.3 Modifying Motor Node ID​

Example: Set the motor ID to 5.

IDDLCData (HEX)Description
60x823 30 25 00 05 00 00 00Set motor ID to 5

4.4 Set Mechanical Zero Procedure​

When performing zero-position calibration (Set Mechanical Zero), ensure proper state transitions as follows (note: standard calibration requires disabling the motor when saving):

  1. First enable the motor and move it to the desired mechanical zero position.
  2. Send the calibration command: 60x 23 31 25 00 01 00 00 00.
  3. Read back the current actual position and verify that it reads 0, indicating successful zero calibration.
  4. After disabling the motor and engaging the brake, send the calibration reset command as required by the firmware.
  5. Re-enable the motor; normal control can resume once Brake Release completes.
IDDLCData (HEX)Description
60x823 31 25 00 01 00 00 00Set Mechanical Zero

4.5 Reading Motor Position​

IDDLCData (HEX)Description
60x840 64 60 00 00 00 00 00Read actual motor position
58x843 64 60 00 00 00 00 00Actual motor position response

Position feedback is parsed in Little-Endian order (low byte first, high byte last). For example, FE 3F reconstructs to 0x3FFE (16382 in decimal); dividing by 182 gives approximately 90 deg.

IDFrame FormatFrame TypeDLCCAN FDData
0x601StandardData Frame8CAN FD43 64 60 00 00 00 00 00
0x581StandardData Frame8CAN FD43 64 60 00 FE 3F 00 00

4.6 Watchdog, Position Limits, and Heartbeat​

warning

Disabling the watchdog and position limit protections reduces on-site safety protection; use this only in controlled debugging scenarios where risks are clearly understood.

FunctionIDDLCData (HEX)Description
Disable watchdog and limit protection60x823 50 26 00 01 00 00 00Disables the 500 ms watchdog protection and position limit protection
Set heartbeat producer time60x82B 17 10 00 D0 07 00 00Sets heartbeat interval to 2000 ms; reverts to default after power cycle

4.7 Software Position Limits and CAN Bit Rate​

When setting positive and negative software limits, the motor must be disabled; save to Flash after configuration.

FunctionIDDLCData (HEX)Description
Set positive limit60x823 7D 60 02 30 7F 00 00Set positive position limit
Read negative limit60x840 7D 60 01 00 00 00 00Read sub-index 01 (min position limit)
Set negative limit60x823 7D 60 01 C8 80 FF FFSet negative position limit
Read positive limit60x840 7D 60 02 00 00 00 00Read sub-index 02 (max position limit)

0x2540:00 has been extended into a general CAN communication bit-rate configuration object, rather than representing only the CAN FD data phase baud rate. Written values are saved to BootPublic and take effect after a reset, reboot, or power cycle.

CAN communication rate values:

Write ValueCommunication Mode
0Classic CAN 500K
1Classic CAN 1M
2CAN FD 1M/1M, BRS disabled
3CAN FD 1M/2M, BRS enabled
4CAN FD 1M/5M, BRS enabled
IDDLCData (HEX)Description
60x840 40 25 00 00 00 00 00Read current CAN communication rate configuration
60x823 40 25 00 04 00 00 00Set to CAN FD 1M/5M with BRS enabled

For complete usage instructions and precautions, refer to TN0002 CANopen Communication Extended Features.

4.8 SDO Profile Position Mode Example​

In position mode, the profile velocity refers to the reducer output shaft speed.

StepIDDLCData (HEX)Description
Ready to switch on60182B 40 60 00 06 00 00 00Ready to switch on
Brake Release60182B 40 60 00 07 00 00 00Release mechanical brake (Switched on)
Enable motor60182B 40 60 00 0F 00 00 00Motor operation enabled
Set mode60182F 60 60 00 01 00 00 00Set Profile Position mode
Set acceleration601823 83 60 00 D0 07 00 00Acceleration 2000 RPM/s; motor-side range 0..10000
Set deceleration601823 84 60 00 D0 07 00 00Deceleration 2000 RPM/s; motor-side range 0..10000
Set velocity601823 81 60 00 0A 00 00 00Output shaft velocity 10 RPM, range 0..30
Set target position601823 7A 60 00 00 40 00 00Target position range -32767..32768
Start absolute motion60182B 40 60 00 4F 00 00 00Motor starts absolute positioning motion
Stop motion60182B 40 60 00 0F 00 00 00Motor stops motion

4.9 SDO Velocity Mode Example​

Both velocity and acceleration in the velocity loop are defined at the motor shaft side.

StepIDDLCData (HEX)Description
Ready to switch on60182B 40 60 00 06 00 00 00Ready to switch on
Brake Release60182B 40 60 00 07 00 00 00Release mechanical brake
Enable motor60182B 40 60 00 0F 00 00 00Motor operation enabled
Set mode60182F 60 60 00 03 00 00 00Write 6060h=3 to enter Velocity mode; readback project mode is 2
Set acceleration601823 83 60 00 E8 03 00 00Acceleration 1000 RPM/s, range 0..10000
Set deceleration601823 84 60 00 E8 03 00 00Deceleration 1000 RPM/s, range 0..10000
Set target velocity601823 FF 60 00 F4 01 00 00Set velocity to 500 RPM

4.10 SDO Current Mode & Torque Sensor Mode Example​

It is recommended to keep the maximum current at its default value matching the motor's peak current rating.

StepIDDLCData (HEX)Description
Ready to switch on60182B 40 60 00 06 00 00 00Ready to switch on
Brake Release60182B 40 60 00 07 00 00 00Release mechanical brake
Enable motor60182B 40 60 00 0F 00 00 00Motor operation enabled
Set mode60182F 60 60 00 0A 00 00 00Write 6060h=10 (compatible CST input) to enter project Current mode; readback project mode is 5
Set target current60182B 71 60 00 F4 01 00 00Set target current 500 mA; refer to motor specifications for valid range

You may also write 6060h=5 to enter the native project Current mode directly. If the master uses standard CiA 402 CST numbering, continue using 6060h=10.

Torque Sensor Closed-Loop Mode applies only to models configured with a Torque Sensor and torque loop. This mode uses the native project input 6060h=7, with the target torque written via 6071h in units of 0.1 Nm:

StepIDDLCData (HEX)Description
Ready to switch on60182B 40 60 00 06 00 00 00Ready to switch on
Brake Release60182B 40 60 00 07 00 00 00Release mechanical brake
Enable motor60182B 40 60 00 0F 00 00 00Motor operation enabled
Set mode60182F 60 60 00 07 00 00 00Write 6060h=7 to enter Torque Sensor Closed-Loop Mode
Set target torque60182B 71 60 00 0A 00 00 00Raw value 10, corresponding to 1.0 Nm joint-side target torque

4.11 PI Gains and Saving to Flash​

ParameterIDDLCData (HEX)Description
Current Loop P601823 32 25 00 00 00 00 00Set motor current loop P
Current Loop I601823 33 25 00 00 00 00 00Set motor current loop I
Velocity Loop P601823 34 25 00 00 00 00 00Set motor velocity loop P
Velocity Loop I601823 35 25 00 00 00 00 00Set motor velocity loop I
Position Loop P601823 36 25 00 00 00 00 00Set motor position loop P
Position Loop I601823 37 25 00 00 00 00 00Set motor position loop I

Save written PI gains and maximum current to Flash:

IDDLCData (HEX)Description
601823 39 25 00 01 00 00 00Save to Flash

Read PI parameters:

ParameterData (HEX)
Read motor current loop P40 32 25 00 00 00 00 00
Read motor current loop I40 33 25 00 00 00 00 00
Read motor velocity loop P40 34 25 00 00 00 00 00
Read motor velocity loop I40 35 25 00 00 00 00 00
Read motor position loop P40 36 25 00 00 00 00 00
Read motor position loop I40 37 25 00 00 00 00 00
Read motor max current40 38 25 00 00 00 00 00

4.12 SDO Status & Feedback Reading Examples​

IDDLCData (HEX)DescriptionParsing
601840 78 60 00 00 00 00 00Read actual motor current-
58184B 78 60 00 45 01 00 00Actual motor current response0x0145 = 325 decimal, unit: mA
601840 64 60 00 00 00 00 00Read actual motor position-
581843 64 60 00 FE 3F 00 00Actual motor position response0x3FFE = 16382; divided by 182 ~= 90 deg; 65536 counts/rev corresponds to -180..180 deg
601840 6C 60 00 00 00 00 00Read actual motor velocity-
581843 6C 60 00 F9 01 00 00Actual motor velocity response0x01F9 converts to 50.5 RPM
601840 3F 60 00 00 00 00 00Read motor fault code-
58184B 3F 60 00 00 00 00 00Motor fault code responseSee Troubleshooting section for fault code definitions
601840 41 60 00 00 00 00 00Read motor statusword-
58184B 41 60 00 00 00 00 00Motor statusword response0x0021: Ready to switch on; 0x0023: Brake Release (Switched on); 0x0027: Operation enabled; 0x0008: Fault state
601840 62 26 00 00 00 00 00Read MOSFET temperature sensor-
581843 62 26 00 18 01 00 00Temperature sensor response0x0118 = 280 decimal, i.e., 28.0 degC
601840 63 26 00 00 00 00 00Read motor winding temperature sensor-
581843 63 26 00 18 01 00 00Temperature sensor response0x0118 = 280 decimal, i.e., 28.0 degC
tip

0x603F returns legacy manufacturer-compatible fault codes. For V2.0 and later firmware, to read the V2.0 diagnostic error codes, refer to FC0001 V2.0 Error Codes & SDO Reading and read 0x4500 to obtain the lower 16 bits of the full V2.0 diagnostic ID.

5. CAN FD Custom PDO Control Examples​

5.1 Single-Actuator Control Frame​

Sent from the host controller to an individual actuator:

FieldLengthDescription
StdID11 bit0x100 + Dev_ID
DLC-7
[0].Bit[7]1 bitEnable control: 0 = Disable, 1 = Enable
[0].Bit[6]1 bitBrake control: 0 = Brake engaged, 1 = Brake Release
[0].Bit[5]1 bitClear fault control: 0 = Default, 1 = Fault reset
[0].Bit[4:1]4 bitProject mode value: 0x01 Profile Position, 0x02 Profile Velocity, 0x03 CSP, 0x04 CSV, 0x05 Current, 0x06 MIT, 0x07 Torque Sensor Closed-Loop
[0].Bit[0]-Reserved
[1]..[2]16 bitTarget Parameter 1 (Big-Endian). Position mode: output-side target position (-32768..32767 -> -180..180 deg); Velocity mode: motor-side target velocity (RPM); Current mode: target Iq current (mA); Torque Sensor Closed-Loop mode: joint-side target torque (0.1 Nm)
[3]..[4]16 bitTarget Parameter 2 (Big-Endian). Profile Position and Profile Velocity modes: profile acceleration/deceleration, range 0..20000, unit RPM/s
[5]..[6]16 bitTarget Feedforward Parameter (Big-Endian). Position mode: output-side profile velocity; reserved in other modes

5.2 Single-Axis Control Frame Examples​

The examples below assume motor Dev_ID = 1.

No.IDProtocolDLCDescriptionData
00x101CAN FD7PP mode move to 0 cnt, accel/decel 2000, speed 5C2 00 00 07 D0 00 05
10x101CAN FD7PP mode move to 16384 cnt, accel/decel 1000, speed 8C2 40 00 03 E8 00 08
20x101CAN FD7PP mode move to -16384 cnt, accel/decel 1000, speed 8C2 C0 00 03 E8 00 08
30x101CAN FD7Velocity mode, speed 500, accel/decel 1000C4 01 F4 03 E8 00 00
40x101CAN FD7Velocity mode, speed -500, accel/decel 1000C4 FE 0C 03 E8 00 00
50x101CAN FD7Current mode, current 1000CA 03 E8 00 00 00 00
60x101CAN FD7Current mode, current -1000CA FC 18 00 00 00 00
70x101CAN FD7CSP mode move to 50 cntC6 00 32 00 00 00 00
80x101CAN FD7CSP mode move to 100 cntC6 00 64 00 00 00 00
90x101CAN FD7Torque Sensor Closed-Loop mode, target torque 1.0 NmCE 00 0A 00 00 00 00

The mode field in custom fast-control frames uses the internal project mode value directly without applying 6060h compatibility mapping. MIT Impedance Control uses dedicated single-axis (0x110 + Dev_ID) or 64-byte multi-axis (0x210) fast-control frames; see TN0001 CAN FD MIT Mode and Force Control Tuning Guide for details.

Simple feedback example:

IDFrame FormatFrame TypeDLCCAN FDData
0x101StandardData Frame7CAN FDC2 00 00 07 D0 00 05
0x301StandardData Frame12CAN FDFF FE 00 00 FF E2 00 00 01 04 01 D0
0x081StandardData Frame8CAN FD02 00 00 00 00 00 00 00

5.3 Multi-Actuator Control Frame​

The multi-actuator control frame broadcasts commands to control up to 8 motors simultaneously.

FieldLengthDescription
StdID11 bit0x200
DLC-64
[0]..[6]7 bytesControl command sub-packet 1
[7]..[13]7 bytesControl command sub-packet 2
[14]..[20]7 bytesControl command sub-packet 3
[21]..[27]7 bytesControl command sub-packet 4
[28]..[34]7 bytesControl command sub-packet 5
[35]..[41]7 bytesControl command sub-packet 6
[42]..[48]7 bytesControl command sub-packet 7
[49]..[55]7 bytesControl command sub-packet 8
[56]..[63]8 bytesTarget actuator ID (Dev_ID) for each corresponding sub-packet

Each 7-byte control sub-packet has the exact same layout as the single-actuator control frame. Pad unused sub-packets and ID slots with 00.

7-axis control example:

0x200:
D0 16 E5 00 00 00 00 D0 2D 15 00 00 00 00 D0 17 EA 00 00 00 00
D0 FD 65 00 00 00 00 D0 E1 07 00 00 00 00 D0 F4 E9 00 00 00 00
D0 08 C8 00 00 00 00 00 00 00 00 00 00 00 01 02 03 04 05 06 07
00

0x301: 16 E3 00 00 F5 2D 01 98 01 DC 70 00
0x302: 2D 17 00 00 F7 B0 01 B5 01 DE 70 00
0x303: 18 41 FF A0 F4 49 01 BE 01 C8 70 00
0x304: FD 78 FF E8 04 50 01 AB 01 E0 70 00
0x305: E2 80 FE 8B FA CD 01 BE 01 F4 70 00
0x306: F5 51 FF A6 FF 2F 01 CC 01 E4 70 00
0x307: 08 B2 00 01 FF C3 01 C2 01 E2 70 00

5.4 MIT Impedance Control Entry Points​

MIT mode supports both a fixed PDO4/MIT channel under full CANopen and custom single-axis / multi-axis fast-control entry points. All three entry points share the same 8-byte 5-tuple MIT bit-packing scheme:

Entry PointCAN IDPayload BytesDescription
PDO4/MIT Fixed Channel0x500 + Dev_ID8Used in full CANopen mode; payload is a fixed 8B MIT packet. Does not include a control byte—requires prior entry into Operation enabled + MIT mode, and is not parsed via OD 1603h mapping
MIT Single-Axis Fast Control0x110 + Dev_ID9 (padded to 12B CAN FD)Byte0 carries enable, Brake Release, fault clear, and internal mode bits; Byte1..8 match the 8B PDO4/MIT payload
MIT Multi-Axis Fast Control0x21064Carries up to six 9B MIT sub-frames using the same bit-packing scheme as single-axis fast control

For the complete MIT workflow, 8B bit-packing C code, and ready-to-send frame examples, refer to TN0001 CAN FD MIT Mode and Force Control Tuning Guide.

6. Actuator Feedback Frame​

Actuator feedback frames can be triggered in three ways:

  1. Host controller sends a SYNC frame with ID 0x80.
  2. Triggered automatically upon receiving a multi-actuator control frame.
  3. Triggered automatically upon receiving a single-axis control frame.

Sent from the actuator to the host controller:

FieldLengthDescription
StdID11 bit0x300 + Dev_ID
DLC-12 bytes
[0]..[1]16 bitLoad-side actual position (Byte[0] high byte, Byte[1] low byte), range -32768..32767 -> -180..180 deg
[2]..[3]16 bitMotor-side actual velocity (int16, Big-Endian), unit: RPM
[4]..[5]16 bitActual current Iq (int16, Big-Endian), unit: mA
[6]..[7]16 bitError code (Big-Endian), see Troubleshooting fault table
[8]..[9]16 bitMotor winding temperature (int16, Big-Endian), unit: 0.1 degC
[10]8 bitProject mode feedback: 0x01 Profile Position, 0x02 Profile Velocity, 0x03 CSP, 0x04 CSV, 0x05 Current, 0x06 MIT, 0x07 Torque Sensor Closed-Loop
[11].Bit[7]1 bitEnable state: 0 = Disabled, 1 = Enabled
[11].Bit[6]1 bitBrake state: 0 = Brake engaged, 1 = Brake Release
[11].Bit[5]1 bitFault state: 0 = Normal, 1 = Fault active
[11].Bit[4]1 bitPosition reached state: 0 = In motion, 1 = Target reached
[11].Bit[3:0]-Reserved

Feedback parsing example:

DirectionIDFrame FormatFrame TypeBytesCAN FDData
Tx0x101StandardData Frame7CAN FDC2 00 00 07 D0 00 05
Rx0x301StandardData Frame12CAN FD09 E1 FD E5 FF 51 00 00 00 F0 01 C0
DataDecoded Value
09 E113 deg
FD E5-539 RPM
FF 51-175 mA
00 00No fault
00 F024 degC
01Profile Position mode
C01100 0000 binary: Enabled, Brake Release, Normal (no fault), In motion

7. Standard CANopen PDO Configuration​

Standard CANopen PDOs do not come with pre-configured complete mappings and should be configured by the user according to application requirements. Because code snippets converted from the legacy Word manual contained OCR formatting shifts, the configuration procedure is presented below as an exact CAN frame sequence.

Typical PDO mapping sequence (for Node ID 1):

IDFrame TypeFrame FormatLengthDataDescription
0x0701Data FrameStandard0x0100Power-on boot-up message
0x0000Data FrameStandard0x0281 01Reset node
0x0601Data FrameStandard0x082B 17 10 00 C8 00 00 00Configure heartbeat producer time (200 ms)
0x0581Data FrameStandard0x0860 17 10 00 00 00 00 00Response
0x0601Data FrameStandard0x0823 00 18 01 81 01 00 80Disable txPDO1
0x0581Data FrameStandard0x0860 00 18 01 00 00 00 00Disable txPDO1 response
0x0601Data FrameStandard0x0823 01 18 01 81 02 00 80Disable txPDO2
0x0581Data FrameStandard0x0860 01 18 01 00 00 00 00Disable txPDO2 response
0x0601Data FrameStandard0x0823 02 18 01 81 03 00 80Disable txPDO3
0x0581Data FrameStandard0x0860 02 18 01 00 00 00 00Disable txPDO3 response
0x0601Data FrameStandard0x0823 03 18 01 81 04 00 80Disable txPDO4
0x0581Data FrameStandard0x0860 03 18 01 00 00 00 00Disable txPDO4 response
0x0601Data FrameStandard0x0823 00 14 01 01 02 00 80Disable rxPDO1
0x0581Data FrameStandard0x0860 00 14 01 00 00 00 00Disable rxPDO1 response
0x0601Data FrameStandard0x0823 01 14 01 01 03 00 80Disable rxPDO2
0x0581Data FrameStandard0x0860 01 14 01 00 00 00 00Disable rxPDO2 response
0x0601Data FrameStandard0x0823 02 14 01 01 04 00 80Disable rxPDO3
0x0581Data FrameStandard0x0860 02 14 01 00 00 00 00Disable rxPDO3 response
0x0601Data FrameStandard0x0823 03 14 01 01 05 00 80Disable rxPDO4
0x0581Data FrameStandard0x0860 03 14 01 00 00 00 00Disable rxPDO4 response
0x0601Data FrameStandard0x082F 00 18 02 01 00 00 00Set TPDO1 transmission type (every SYNC)
0x0581Data FrameStandard0x0860 00 18 02 00 00 00 00Response
0x0601Data FrameStandard0x082F 00 1A 00 00 00 00 00Clear txPDO1 mapping count
0x0581Data FrameStandard0x0860 00 1A 00 00 00 00 00Response
0x0601Data FrameStandard0x0823 00 1A 01 10 00 41 60Map 6041 Statusword (16 bit)
0x0581Data FrameStandard0x0860 00 1A 01 00 00 00 00Response
0x0601Data FrameStandard0x0823 00 1A 02 10 00 78 60Map 6078 Actual Current (16 bit)
0x0581Data FrameStandard0x0860 00 1A 02 00 00 00 00Response
0x0601Data FrameStandard0x0823 00 1A 03 20 00 64 60Map 6064 Actual Position (32 bit)
0x0581Data FrameStandard0x0860 00 1A 03 00 00 00 00Response
0x0601Data FrameStandard0x082F 00 1A 00 03 00 00 00Enable 3 mapped objects in txPDO1
0x0581Data FrameStandard0x0860 00 1A 00 00 00 00 00Response
0x0601Data FrameStandard0x0823 00 18 01 81 01 00 00Enable txPDO1 with COB-ID 0x181
0x0581Data FrameStandard0x0860 00 18 01 00 00 00 00Response
0x0601Data FrameStandard0x082F 00 14 02 01 00 00 00Set RPDO1 transmission type (synchronous)
0x0581Data FrameStandard0x0860 00 14 02 00 00 00 00Response
0x0601Data FrameStandard0x082F 00 16 00 00 00 00 00Clear rxPDO1 mapping count
0x0581Data FrameStandard0x0860 00 16 01 00 00 00 00Response
0x0601Data FrameStandard0x0823 00 16 01 10 00 40 60Map 6040 Controlword (16 bit)
0x0581Data FrameStandard0x0860 00 16 01 00 00 00 00Response
0x0601Data FrameStandard0x0823 00 16 02 10 00 71 60Map 6071 Target Current / Torque (16 bit)
0x0581Data FrameStandard0x0860 00 16 02 00 00 00 00Response
0x0601Data FrameStandard0x0823 00 16 03 20 00 7A 60Map 607A Target Position (32 bit)
0x0581Data FrameStandard0x0860 00 16 03 00 00 00 00Response
0x0601Data FrameStandard0x082F 00 16 00 03 00 00 00Enable 3 mapped objects in rxPDO1
0x0581Data FrameStandard0x0860 00 16 00 00 00 00 00Response
0x0601Data FrameStandard0x0823 00 14 01 01 02 00 00Enable rxPDO1 with COB-ID 0x201
0x0581Data FrameStandard0x0860 00 14 01 00 00 00 00Response
0x0601Data FrameStandard0x082F 60 60 00 08 00 00 00Write 6060h=8 to select CSP; readback project mode is 3
0x0581Data FrameStandard0x0860 60 60 00 00 00 00 00Response
0x0701Data FrameStandard0x017FNode heartbeat (Pre-Operational)
0x0000Data FrameStandard0x0201 00NMT Start all nodes (enter Operational)
0x0080Data FrameStandard0x00-SYNC frame

8. Encoder Specifications​

8.1 Encoder Resolution & Single-Turn Position Feedback​

The Joint Module achieves full closed-loop control using dual single-turn absolute encoders:

  • Motor-side encoder resolution: 14 bit, i.e., 16384 cnt/rev.
  • Load-side (output) encoder resolution: 16 bit, i.e., 65536 counts per revolution, raw feedback range 0..65535.

When the output shaft crosses the zero mark, the raw single-turn reading wraps around: 65535 -> 0 in the positive direction and 0 -> 65535 in the negative direction. Full closed-loop host algorithms must compensate for this zero-crossing wraparound to avoid transient disturbances.

The 16 bit absolute encoder has an angular error within +/-0.5 deg and repeatability within +/-0.05 deg.

Formula for converting single-turn angle theta to position counts:

position = theta / 360 deg * 65536

For example, when theta = 20 deg:

position = 20 / 360 * 65536 ~= 3641

Equivalent incremental encoder line count: 4096.

8.2 Position Feedback Diagram​

Encoder Position Feedback Diagram

9. Module Connector Pinout​

Because connector tables converted from the legacy Word document contained duplicated OCR entries, only verified module models, connector part numbers, and pin assignments are listed below. Always verify actual wiring against product silkscreen markings, mechanical drawings, or the datasheet shipped with your hardware.

ModelPower ConnectorPower PinoutCommunication ConnectorCommunication Pinout
R120 / R120MAXXT30AW-M.G.Y, AMASS1: G, 2: VINX1251WVS-03HF-LPSW, XKB-Connection1: H, 2: L, 3: G
R102XT30AW-M.G.Y, AMASS1: G, 2: VINX1251WVS-03HF-LPSW, XKB-Connection1: H, 2: L, 3: G
R83XT30AW-M.G.Y, AMASS1: G, 2: VINB03B-XNISK-A-1(LF)(SN), JST1: H, 2: L, 3: G
R68XT30AW-M.G.Y, AMASS1: G, 2: VINX1251WVS-03HF-LPSW, XKB-Connection1: H, 2: L, 3: G
R58DL15006-2AB, Delilai (德利来)1: G, 2: 24+DL12503-3AB, Delilai (德利来)1: G, 2: L, 3: H
R48B02B-XNISK-A-1(LF)(SN), JST1: G, 2: VINB03B-ZESK-1D(LF)(SN), JST1: G, 2: L, 3: H
R48-101-DNFB02B-XNISK-A-1(LF)(SN), JST1: G, 2: VINB03B-ZESK-1D(LF)(SN), JST1: G, 2: L, 3: H
R83-101-FBNXT30AW-M.G.Y, AMASS1: G, 2: VINB03B-XNISK-A-1(LF)(SN), JST1: H, 2: L, 3: G
R80-50-13NSFNXT30U-M Female, AMASS1: G, 2: 24+DL12503-3AB, Delilai (德利来)1: G, 2: L, 3: H
R68-101-liteXT30AW-M.G.Y, AMASS1: G, 2: VINX1251WVS-03HF-LPSW, XKB-Connection1: H, 2: L, 3: G
R48-101-liteDL15006-2AB, Delilai (德利来)Refer to datasheetDL12503-3AB / HC-0.8-6PLTHC-0.8-6PLT: 1: G, 2: L, 3: H, 4: G, 5: L, 6: H

10. Troubleshooting & Fault Codes​

When the motor reports an abnormal alarm, refer to the fault codes below.

Legacy Compatibility Codes Note

The table below lists legacy compatibility fault codes applicable to existing parsing workflows on corresponding products and firmware. Firmware supporting V2.0 diagnostic IDs uses 0xDDSS encoding; see FC0001 V2.0 Error Codes & SDO Reading for reading methods, and FC0002 Joint Module Fault Alarm & Protection Logic Guide for protection actions and troubleshooting procedures.

Fault NameTrigger ConditionProtection LevelFault Clearing MethodFault CodeNotes
UndervoltageBus voltage < 40 VFast ProtectionPower cycle to clear0x0002Hardware undervoltage threshold is 35 V
OvervoltageBus voltage > 72 VGeneral ProtectionPower cycle to clear0x0001-
OvertemperatureMotor winding NTC > 95 degC for 100 ms, or drive NTC > 100 degC for 100 ms; temperature rise-rate protection active above 80 degCGeneral ProtectionClear via command after cooling below 85 degC0x0004-
Motor StallMotor Iq reaches or exceeds configured max current for 2 sCurrent-Limit ProtectionPower cycle to clear0x0008-
OverloadMotor Iq current integral exceeds configured thresholdGeneral ProtectionPower cycle to clear0x0010-
Excessive Velocity Tracking ErrorError between desired and actual velocity > 320 RPM for 20 ms (R120 / R120MAX only; 200 RPM threshold on other modules)Fast ProtectionPower cycle to clear0x0020May trigger under sudden load impact; gradual overload may trigger stall or velocity tracking error
Positive Limit ProtectionLimit photo-sensor triggered or software positive angle limit exceeded while target velocity is in the positive limit direction. Default software positive limit: 32767Fast ProtectionClear via command; motion allowed in opposite direction0x0040-
Negative Limit ProtectionLimit photo-sensor triggered or software negative angle limit exceeded while target velocity is in the negative limit direction. Default software negative limit: -32767Fast ProtectionClear via command; motion allowed in opposite direction0x0080-
Output Encoder AbnormalityCompares velocity calculated from output encoder against motor-side velocity; triggers when output encoder velocity is 0 while motor side is 100 RPM for 20 ms (and vice versa)Fast ProtectionPower cycle to clear0x0100-
Excessive Position JumpTarget position increment in CSP mode > 100 cnt per 1 ms cycleServo holds current positionClear via command0x0200-
Current Sensing FaultCurrent sensing zero-offset out of valid range during initializationFast ProtectionPower cycle to clear0x0400-
Excessive Current Tracking ErrorError between target and feedback current > 10 A for 20 ms (threshold scaled by rated current)Fast ProtectionPower cycle to clear0x0800May be caused by phase loss or abnormal motor parameters
Excessive Position Tracking ErrorError between desired and actual position > 2000 cnt for 20 msFast ProtectionPower cycle to clear0x1000-

Protection level descriptions:

Protection LevelProtection Action Sequence
General ProtectionDecelerate speed below threshold; engage brake; wait 100 ms; turn off PWM
Fast ProtectionTurn off PWM immediately; engage brake
Current-Limit ProtectionClamp current to 50% of max current; engage brake; wait 100 ms; turn off PWM