FC0002 Joint Module Fault Alarm and Protection Logic Guide

ItemDetails
Document NumberFC0002
RevisionRev. 1.0.1
Applicable ProductsJxServo Joint Module / Integrated Communication Module
Applicable FirmwareDelivery firmware supporting V2.0 diagnostic IDs
LanguageEnglish
Last Updated2026-07-30

This guide explains the Warning (WARN), Fault (FLT), and Trip (TRIP) events that a Joint Module may report during operation, together with their corresponding protection actions, clearing methods, and field troubleshooting procedures.

Different product models, hardware platforms, and delivery firmware builds may enable only a subset of these diagnostic items, and their thresholds, confirmation times, protection actions, and hardware signal wiring may also vary. Values listed in this document represent common reference configurations; in actual deployment, refer to the release documentation, delivery firmware, and device parameters of your specific product model.

Safety Notice

After a FAULT or TRIP occurs, never repeatedly clear faults or force servo Enable while the underlying cause remains present. First bring the equipment to a safe state, eliminate power supply, wiring, mechanical binding, overload, or feedback anomalies, then execute a fault reset, and verify operation starting from no-load, low-speed conditions.

1. Fault Code Reading and Encoding Rules​

The lower 16 bits of a V2.0 diagnostic ID follow the 0xDDSS format:

  • DD: Fault domain, distinguishing categories such as power, drive/current, sensor, control, and communication.
  • SS: Fault sub-item, identifying the specific anomaly within that fault domain.
  • Example: 0x0507 denotes fault domain 0x05 and sub-item 0x07, corresponding to "Excessive velocity tracking error".

When reading fault information over CANopen:

  • 0x603F:00 reads the currently active or actually transmitted CANopen error code.
  • 0x4500:00 reads the lower 16 bits of the V2.0 diagnostic ID for the most recent warning or fault.
  • The 0x80 + NodeID Emergency (EMCY) Frame also carries severity and snapshot context data for analyzing actual trigger values, thresholds, or hardware flags.

For complete SDO frame formats, Emergency (EMCY) Frame parsing, and legacy compatibility code mappings, refer to FC0001 V2.0 Fault Code Encoding and SDO Reading Guide.

2. Fault Severity Levels and Protection Actions​

2.1 Fault Severity Levels​

LevelMeaningTypical Handling
Warning (WARN)Abnormal trend or operating quality issueLogged as a warning; the fault manager does not actively stop the drive
Fault (FAULT)Anomaly affecting safety or control reliabilityExecutes configured protection action; reset after eliminating the root cause
Trip (TRIP)Severe anomaly in hardware or critical feedback linkImmediately stops motion output and enters latched fault protection

2.2 Protection Actions and Clearing Modes​

TypeMeaning
Log Only (ACT_REC)Logs the warning without actively altering servo output
Controlled Stop / Hold (ACT_DSTOP / ACT_DHOLD)Decelerates to a stop along a configured ramp, then shuts off output, engages the brake, or holds position depending on hardware configuration
Emergency Stop (ACT_ESTOP)Revokes servo Enable and stops motion output, executing power-stage shutoff and brake engagement per hardware configuration
Auto Clear (CLR_AUTO)Automatically clears once the abnormal condition disappears and recovery criteria are satisfied
Host Reset (CLR_HOST)Cleared via fault reset from the host application or master controller after eliminating the cause and ensuring the servo is Disabled

3. General Handling Workflow​

  1. Record the diagnostic code along with load, speed, supply voltage, motor temperature, and ambient operating conditions at the time of occurrence.
  2. Locate the fault in the Quick Index below, then inspect its trigger conditions and troubleshooting recommendations under the corresponding fault domain.
  3. Prioritize ruling out hardware issues such as short circuits, wiring faults, power supply anomalies, mechanical overload, poor heat dissipation, brake issues, encoders, and sensors.
  4. Confirm that the trigger condition has been eliminated and ensure the servo is Disabled.
  5. Issue a "Clear Fault / Fault Reset" command from the host tool or master controller; power-cycle or recalibrate when explicitly required by the fault item.
  6. After a successful reset, test under no-load and low-speed conditions first before gradually returning to normal operating loads.

4. Fault Code Quick Index​

Fault CodeFault NameLevelTypical Protection Action
0x0001Electrical angle zero not calibratedFAULTEmergency Stop
0x0100DC bus overvoltageFAULTEmergency Stop
0x0101DC bus undervoltageFAULTEmergency Stop
0x0102DC bus hardware overvoltage tripTRIPEmergency Stop
0x0103DC bus hardware overcurrent tripTRIPEmergency Stop
0x0200Software overcurrent (Iq over-limit)FAULTEmergency Stop
0x0201Phase U hardware overcurrentTRIPEmergency Stop
0x0203Phase V hardware overcurrentTRIPEmergency Stop
0x0204Drive over-temperature warningWARNLog Only
0x0205Drive over-temperature faultFAULTEmergency Stop
0x0206Phase U software overcurrentTRIPEmergency Stop
0x0207Phase V software overcurrentTRIPEmergency Stop
0x0302Motor over-temperature warningWARNLog Only
0x0303Motor over-temperature faultFAULTEmergency Stop
0x0400Encoder update timeoutTRIPEmergency Stop
0x0401Encoder read failureWARNLog Only
0x0402Torque communication faultFAULTControlled Stop
0x0403Torque signal faultFAULTControlled Stop
0x0404Torque plausibility faultFAULTControlled Stop
0x0406Encoder status warningWARNLog Only
0x0407Encoder status errorFAULTEmergency Stop
0x0408Current offset calibration failureFAULTEmergency Stop
0x0500Excessive position tracking errorWARNLog Only
0x0501Torque control faultFAULTEmergency Stop
0x0507Excessive velocity tracking errorFAULTEmergency Stop
0x0508Software stallFAULTEmergency Stop
0x0509Velocity command exceeds upper limitWARNLog Only
0x050ARunaway / overspeed protectionFAULTEmergency Stop
0x050BExcessive current tracking errorFAULTEmergency Stop
0x0600Communication heartbeat lostWARNProject-configurable
0x0603CAN communication BusOffWARNLog Only
0x0705Positive optical limit exceededFAULTEmergency Stop
0x0706Negative optical limit exceededFAULTEmergency Stop
0x0707Positive software limit exceededFAULTEmergency Stop
0x0708Negative software limit exceededFAULTEmergency Stop

5. Detailed Protection Logic​

5.1 System and Calibration 0x00​

0x0001 Electrical Angle Zero Not Calibrated​

ItemDescription
LevelFault (FAULT)
Trigger ConditionAt power-up or before entering closed-loop control, the electrical angle zero parameter is detected as invalid, missing, or uncalibrated.
Protection ActionImmediately revokes servo Enable and stops motion output; executes power-stage shutoff and brake engagement per hardware configuration, entering fault protection state.
Clearing MethodComplete electrical angle zero calibration and save parameters, ensure the servo is Disabled, then execute a fault reset or power-cycle the device.
TroubleshootingCheck whether initial assembly calibration was completed, whether parameters were saved properly, whether the parameter Flash region is intact, and whether firmware matches parameter version.

5.2 DC Bus and Power Supply 0x01​

0x0100 DC Bus Overvoltage​

ItemDescription
LevelFault (FAULT)
Trigger ConditionDC bus voltage exceeds the project threshold continuously for the confirmation duration; a typical reference setting is ≥ 68 V for ≥ 10 ms.
Protection ActionImmediately revokes servo Enable and stops motion output; executes power-stage shutoff and brake engagement per hardware configuration.
Clearing MethodEliminate the cause, ensure the servo is Disabled, and execute a fault reset; reported again if the trigger condition persists.
TroubleshootingCheck whether input supply voltage is too high, whether rapid deceleration causes regenerative voltage rise, power supply regeneration absorption capacity, bus capacitance, and braking circuitry.

0x0101 DC Bus Undervoltage​

ItemDescription
LevelFault (FAULT)
Trigger ConditionDC bus voltage drops below the project threshold continuously for the confirmation duration; common reference thresholds are 40 V for 48 V modules and 20 V for 24 V modules, typically confirmed over 2 ms.
Protection ActionImmediately revokes servo Enable and stops motion output; executes power-stage shutoff and brake engagement per hardware configuration.
Clearing MethodEliminate the cause, ensure the servo is Disabled, and execute a fault reset; reported again if the trigger condition persists.
TroubleshootingCheck for supply voltage sag, insufficient PSU power rating, cable voltage drop, connector contact resistance, and power-up sequencing; measure actual DC bus voltage at the module terminals.

0x0102 DC Bus Hardware Overvoltage Trip​

ItemDescription
LevelTrip (TRIP)
Trigger ConditionHardware overvoltage comparator or protection signal triggered; this hardware event bypasses normal software debounce timers.
Protection ActionImmediately revokes servo Enable and stops motion output; executes power-stage shutoff and brake engagement per hardware configuration.
Clearing MethodEliminate the cause, ensure the servo is Disabled, and execute a fault reset; reported again if the trigger condition persists.
TroubleshootingInspect supply surges, regenerative voltage spikes, comparator threshold hardware, and noise on protection lines. Independent reporting depends on whether the delivery hardware wires this dedicated comparator signal.

0x0103 DC Bus Hardware Overcurrent Trip​

ItemDescription
LevelTrip (TRIP)
Trigger ConditionPower stage hardware BRK or overcurrent comparator triggered and reported via platform interrupt.
Protection ActionImmediately revokes servo Enable and stops motion output; executes power-stage shutoff and brake engagement per hardware configuration.
Clearing MethodEliminate the cause, ensure the servo is Disabled, and execute a fault reset; reported again if the trigger condition persists.
TroubleshootingInspect for phase-to-phase or phase-to-ground shorts, severe mechanical shock loads, damaged power MOSFETs, current sensing faults, or comparator noise. Some platforms report this unified code without distinguishing Phase U/V.

5.3 Drive, Current, and Power Stage 0x02​

0x0200 Software Overcurrent (Iq Over-Limit)​

ItemDescription
LevelFault (FAULT)
Trigger ConditionSoftware detects Iq current exceeding the project threshold continuously; reference configuration is 95% of peak phase current for 50 ms.
Protection ActionImmediately revokes servo Enable and stops motion output; executes power-stage shutoff and brake engagement per hardware configuration.
Clearing MethodEliminate the cause, ensure the servo is Disabled, and execute a fault reset; reported again if the trigger condition persists.
TroubleshootingDisabled by default in many standard projects. When enabled, inspect mechanical overload, current-loop gains, step command transients, and current sensing accuracy.

0x0201 Phase U Hardware Overcurrent​

ItemDescription
LevelTrip (TRIP)
Trigger ConditionDrive hardware BRK protection triggered and identified by the hardware platform specifically as Phase U overcurrent.
Protection ActionImmediately revokes servo Enable and stops motion output; executes power-stage shutoff and brake engagement per hardware configuration.
Clearing MethodEliminate the cause, ensure the servo is Disabled, and execute a fault reset; reported again if the trigger condition persists.
TroubleshootingInspect Phase U wiring, winding insulation, power MOSFETs, current-sense circuitry, hardware comparators, and mechanical shock. Platforms without per-phase comparator identification report 0x0103 instead.

0x0203 Phase V Hardware Overcurrent​

ItemDescription
LevelTrip (TRIP)
Trigger ConditionDrive hardware BRK protection triggered and identified by the hardware platform specifically as Phase V overcurrent.
Protection ActionImmediately revokes servo Enable and stops motion output; executes power-stage shutoff and brake engagement per hardware configuration.
Clearing MethodEliminate the cause, ensure the servo is Disabled, and execute a fault reset; reported again if the trigger condition persists.
TroubleshootingInspect Phase V wiring, winding insulation, power MOSFETs, current-sense circuitry, hardware comparators, and mechanical shock. Platforms without per-phase comparator identification report 0x0103 instead.

0x0204 Drive Over-Temperature Warning​

ItemDescription
LevelWarning (WARN)
Trigger ConditionDrive PCB or MOSFET temperature reaches the warning threshold continuously for the confirmation sample count; reference threshold is 90 °C over 2000 diagnostic samples.
Protection ActionLogs the warning only; the fault manager does not actively alter servo output.
Clearing MethodClears automatically once temperature drops and satisfies auto-recovery hysteresis criteria.
TroubleshootingReduce load duty cycle and ambient temperature; inspect heatsink mounting, thermal interface material, airflow, and NTC sensor readings. Derating load proactively during the warning stage is recommended.

0x0205 Drive Over-Temperature Fault​

ItemDescription
LevelFault (FAULT)
Trigger ConditionDrive PCB or MOSFET temperature reaches the fault threshold continuously; reference threshold is 110 °C confirmed over 200 ms.
Protection ActionImmediately revokes servo Enable and stops motion output; executes power-stage shutoff and brake engagement per hardware configuration.
Clearing MethodActive fault status clears automatically once temperature cools below recovery threshold; after stopping, a fresh servo Enable command is still required to resume motion.
TroubleshootingCheck sustained overload, aggressive acceleration/deceleration duty cycles, thermal mounting, ambient temperature, and temperature sensing. Do not repeatedly force servo Enable before the drive has cooled down.

0x0206 Phase U Software Overcurrent​

ItemDescription
LevelTrip (TRIP)
Trigger ConditionTriggers immediately upon entry into the software Phase U instantaneous overcurrent check.
Protection ActionImmediately revokes servo Enable and stops motion output; executes power-stage shutoff and brake engagement per hardware configuration.
Clearing MethodEliminate the cause, ensure the servo is Disabled, and execute a fault reset; reported again if the trigger condition persists.
TroubleshootingCheck Phase U current sensing, phase short circuits, drive power stage, and current-loop gains. Independent reporting depends on the delivery platform and firmware build.

0x0207 Phase V Software Overcurrent​

ItemDescription
LevelTrip (TRIP)
Trigger ConditionTriggers immediately upon entry into the software Phase V instantaneous overcurrent check.
Protection ActionImmediately revokes servo Enable and stops motion output; executes power-stage shutoff and brake engagement per hardware configuration.
Clearing MethodEliminate the cause, ensure the servo is Disabled, and execute a fault reset; reported again if the trigger condition persists.
TroubleshootingCheck Phase V current sensing, phase short circuits, drive power stage, and current-loop gains. Independent reporting depends on the delivery platform and firmware build.

5.4 Motor Temperature 0x03​

0x0302 Motor Over-Temperature Warning​

ItemDescription
LevelWarning (WARN)
Trigger ConditionMotor temperature reaches the warning threshold continuously for the confirmation sample count; reference threshold is 90 °C over 2000 diagnostic samples.
Protection ActionLogs the warning only; the fault manager does not actively alter servo output.
Clearing MethodClears automatically once temperature drops and satisfies auto-recovery hysteresis criteria.
TroubleshootingReduce load torque or phase current; inspect mechanical friction, ambient cooling, motor thermistor wiring, and thermal parameters. Avoid sustained heavy-load operation while the warning remains active.

0x0303 Motor Over-Temperature Fault​

ItemDescription
LevelFault (FAULT)
Trigger ConditionMotor temperature reaches the fault threshold continuously; reference threshold is 110 °C confirmed over 200 ms.
Protection ActionImmediately revokes servo Enable and stops motion output; executes power-stage shutoff and brake engagement per hardware configuration.
Clearing MethodActive fault status clears automatically once temperature cools below recovery threshold; after stopping, a fresh servo Enable command is still required to resume motion.
TroubleshootingInspect mechanical binding, sustained overload, phase current levels, holding brake release state, heat dissipation conditions, and temperature sensor health. Allow the motor to cool thoroughly before resuming test runs.

5.5 Encoder, Torque Sensor, and Sampling 0x04​

0x0400 Encoder Update Timeout​

ItemDescription
LevelTrip (TRIP)
Trigger ConditionEncoder consecutively fails to produce valid position updates, or the fast protection path determines position feedback is unavailable.
Protection ActionImmediately revokes servo Enable and stops motion output; executes power-stage shutoff and brake engagement per hardware configuration.
Clearing MethodEliminate the cause, ensure the servo is Disabled, and execute a fault reset; reported again if the trigger condition persists.
TroubleshootingCheck encoder connectors at both ends, sensor power supply, and signal integrity; replace the encoder if necessary. This trip indicates loss of a critical closed-loop feedback path.

0x0401 Encoder Read Failure​

ItemDescription
LevelWarning (WARN)
Trigger ConditionThe encoder adaptation layer detects read failures or invalid packets reaching the configured confirmation count.
Protection ActionLogs the warning only; the fault manager does not actively alter servo output.
Clearing MethodEliminate the cause, ensure the servo is Disabled, and execute a fault reset; reported again if the trigger condition persists.
TroubleshootingCheck sensor power, cable shielding, interface timing, and signal integrity. Independent reporting depends on the encoder driver; persistent severe failures escalate to 0x0400.

0x0402 Torque Communication Fault​

ItemDescription
LevelFault (FAULT)
Trigger ConditionWith torque sensor monitoring enabled, no new valid frame is received consecutively or raw sensor data remains stale; reference setting is 15 consecutive confirmations.
Protection ActionExecutes controlled deceleration stop; engages brake or shuts off output once stopped per hardware configuration, or adapts to decelerate-and-hold on brakeless modules.
Clearing MethodEliminate the cause, ensure the servo is Disabled, and execute a fault reset; reported again if the trigger condition persists.
TroubleshootingEnabled only on models equipped with a torque sensor. Inspect sensor power, communication harness, interface configuration, data refresh rate, and main MCU task scheduling.

0x0403 Torque Signal Fault​

ItemDescription
LevelFault (FAULT)
Trigger ConditionTorque feedback exhibits NaN, over-range readings, or abnormal bidirectional spikes; reference full-scale check is 300 N·m, with spike thresholds scaled to the protection limit.
Protection ActionExecutes controlled deceleration stop; engages brake or shuts off output once stopped per hardware configuration, or adapts to decelerate-and-hold on brakeless modules.
Clearing MethodEliminate the cause, ensure the servo is Disabled, and execute a fault reset; reported again if the trigger condition persists.
TroubleshootingEnabled only on models equipped with a torque sensor. Inspect zero-offset drift, mechanical sensor overload, connector contact, EMI noise, and torque calibration parameters.

0x0404 Torque Plausibility Fault​

ItemDescription
LevelFault (FAULT)
Trigger ConditionTorque feedback plausibility check event triggers and reaches confirmation criteria.
Protection ActionExecutes controlled deceleration stop; engages brake or shuts off output once stopped per hardware configuration, or adapts to decelerate-and-hold on brakeless modules.
Clearing MethodEliminate the cause, ensure the servo is Disabled, and execute a fault reset; reported again if the trigger condition persists.
TroubleshootingTypically disabled by default and retained for protocol compatibility. When enabled, inspect consistency across torque estimation sources, zero offset, scale factor, and mechanical sensor mounting.

0x0406 Encoder Status Warning​

ItemDescription
LevelWarning (WARN)
Trigger ConditionEncoder hardware status word or driver adaptation layer reports a recoverable warning condition.
Protection ActionLogs the warning only; the fault manager does not actively alter servo output.
Clearing MethodEliminate the cause, ensure the servo is Disabled, and execute a fault reset; reported again if the trigger condition persists.
TroubleshootingDepending on encoder type, inspect sensor supply voltage, magnetic ring field strength or air gap, temperature, internal status bits, and communication signal quality. Independent reporting depends on encoder driver support.

0x0407 Encoder Status Error​

ItemDescription
LevelFault (FAULT)
Trigger ConditionEncoder hardware status word or driver adaptation layer reports a critical error rendering position feedback untrustworthy.
Protection ActionImmediately revokes servo Enable and stops motion output; executes power-stage shutoff and brake engagement per hardware configuration.
Clearing MethodEliminate the cause, ensure the servo is Disabled, and execute a fault reset; triggers again if the encoder error bit remains asserted.
TroubleshootingInspect the encoder IC, magnetic ring or optical disk mounting, power supply, and communication link. Independent reporting depends on encoder driver support.

0x0408 Current Offset Calibration Failure​

ItemDescription
LevelFault (FAULT)
Trigger ConditionFollowing power-on current zero-offset calibration, Phase U/V ADC offset exceeds the permissible window or exhibits excessive variance, inhibiting normal operation.
Protection ActionImmediately revokes servo Enable and stops motion output; executes power-stage shutoff and brake engagement per hardware configuration.
Clearing MethodEliminate current-sense hardware anomalies while ensuring zero motor current, rerun offset calibration or power-cycle the module, and clear the fault once calibration succeeds.
TroubleshootingInspect shunt resistors, current-sense op-amps, ADC reference voltage, bias network, solder joints, and EMI noise; ensure no drive PWM output or external back-EMF current is present during calibration.

5.6 Control and Motion 0x05​

0x0500 Excessive Position Tracking Error​

ItemDescription
LevelWarning (WARN)
Trigger ConditionAbsolute difference between target position and feedback position exceeds the project threshold continuously; reference thresholds are 0.2 / 0.5 / 0.8 rad confirmed over 10 ms.
Protection ActionLogs the warning only; the fault manager does not actively alter servo output.
Clearing MethodEliminate the cause, ensure the servo is Disabled, and execute a fault reset; reported again if the trigger condition persists.
TroubleshootingCheck payload inertia/load, mechanical binding, step position commands, position-loop gains, peak torque capability, and encoder feedback. Severity is WARN in standard reference profiles.

0x0501 Torque Control Fault​

ItemDescription
LevelFault (FAULT)
Trigger ConditionTorque feedback exceeds the mechanical protection limit, or torque tracking error is excessive while current output is saturated; reference limits are 180 / 280 N·m over 20 confirmations.
Protection ActionImmediately revokes servo Enable and stops motion output; executes power-stage shutoff and brake engagement per hardware configuration.
Clearing MethodEliminate the cause, ensure the servo is Disabled, and execute a fault reset; reported again if the trigger condition persists.
TroubleshootingEnabled only on closed-loop torque control projects. Check external mechanical impacts, external back-driving forces, torque sensor calibration, torque setpoint, current saturation limits, and torque-loop gains.

0x0507 Excessive Velocity Tracking Error​

ItemDescription
LevelFault (FAULT)
Trigger ConditionAbsolute difference between velocity command and feedback velocity exceeds the project threshold continuously; reference thresholds are 500 / 800 / 1000 / 1500 rpm confirmed over 100 / 200 ms.
Protection ActionImmediately revokes servo Enable and stops motion output; executes power-stage shutoff and brake engagement per hardware configuration.
Clearing MethodEliminate the cause, ensure the servo is Disabled, and execute a fault reset; reported again if the trigger condition persists.
TroubleshootingInspect mechanical binding or overload, unreleased holding brake, current limit settings, velocity-loop PID gains, encoder feedback, velocity unit scaling, and abrupt velocity steps.

0x0508 Software Stall​

ItemDescription
LevelFault (FAULT)
Trigger ConditionActual speed remains near zero while Iq command remains high continuously; reference low-speed thresholds are 5 / 20 rpm and high-current thresholds are 65% / 95% of peak phase current over 2 s.
Protection ActionImmediately revokes servo Enable and stops motion output; executes power-stage shutoff and brake engagement per hardware configuration.
Clearing MethodEliminate the cause, ensure the servo is Disabled, and execute a fault reset; reported again if the trigger condition persists.
TroubleshootingInspect mechanical jamming, excessive load, holding brake release, motor phase wiring, motor health, and current limits. In projects where the stall current threshold is set to 0, this check remains inactive.

0x0509 Velocity Command Exceeds Upper Limit​

ItemDescription
LevelWarning (WARN)
Trigger ConditionAbsolute value of the velocity command exceeds the project-defined maximum motor speed; reported once per excursion and re-armed after the command returns within range.
Protection ActionLogs the warning only; the fault manager does not actively alter servo output.
Clearing MethodEliminate the cause, ensure the servo is Disabled, and execute a fault reset; reported again if the trigger condition persists.
TroubleshootingCheck host velocity unit scaling, trajectory planning profiles, control mode transitions, and parameter limits; clamp master velocity setpoints within the rated range of the specific model.

0x050A Runaway / Overspeed Protection​

ItemDescription
LevelFault (FAULT)
Trigger ConditionActual speed reaches approximately 1.15 times the project maximum rated speed continuously for ≥ 50 ms.
Protection ActionImmediately revokes servo Enable and stops motion output; executes power-stage shutoff and brake engagement per hardware configuration.
Clearing MethodEliminate the cause, ensure the servo is Disabled, and execute a fault reset; reported again if the trigger condition persists.
TroubleshootingCheck velocity-loop instability, encoder direction/polarity or gear ratio, motor pole-pair parameters, abrupt setpoint jumps, external back-driving loads, and power-stage faults. Always verify feedback polarity before resetting.

0x050B Excessive Current Tracking Error​

ItemDescription
LevelFault (FAULT)
Trigger ConditionWhile PWM and the current loop are active, Id feedback error or Iq command-to-feedback error exceeds a dynamic threshold continuously for ≥ 15 ms; reference enter/exit relative ratios are 0.55 / 0.35.
Protection ActionImmediately revokes servo Enable and stops motion output; executes power-stage shutoff and brake engagement per hardware configuration.
Clearing MethodEliminate the cause, ensure the servo is Disabled, and execute a fault reset; reported again if the trigger condition persists.
TroubleshootingInspect DC bus voltage, open motor phase wires, power MOSFETs, current sensing, motor inductance/resistance parameters, and current-loop tuning; voltage saturation at high speed can also cause current tracking failure.

5.7 Communication 0x06​

0x0600 Communication Heartbeat Lost​

ItemDescription
LevelWarning (WARN)
Trigger ConditionAfter receiving the first valid CAN frame, no valid bus frame is received for approximately 500 ms continuously; enabled only in selected project profiles.
Protection ActionDetermined by project configuration: logs only when set to ACT_REC, or performs controlled deceleration stop when set to ACT_DSTOP (adapting to decelerate-and-hold on brakeless modules). Legacy watchdog logic may also actively Disable the servo upon initial timeout.
Clearing MethodClears automatically via CLR_AUTO once communication resumes; if the servo was Disabled by protection, a new servo Enable command must be sent.
TroubleshootingVerify continuous master transmission, Node ID, baud rate, bus load, cabling, termination resistors, and master real-time task jitter. Do not rely solely on a single non-redundant frame to maintain heartbeat.

0x0603 CAN Communication BusOff​

ItemDescription
LevelWarning (WARN)
Trigger ConditionCAN controller error counters reach the BusOff state and force a warning report via platform interrupt.
Protection ActionLogs the warning only; the fault manager does not actively alter servo output.
Clearing MethodRestore physical bus integrity, ensure the servo is Disabled, and execute a fault reset; the platform driver may also automatically attempt CAN controller BusOff recovery.
TroubleshootingInspect bit rate and sample point settings, 120 Ω termination resistors, CANH/CANL wiring, common ground reference, short circuits, Node ID collisions, EMI noise, and bus utilization.

5.8 Hardware and Software Limits 0x07​

0x0705 Positive Optical Limit Exceeded​

ItemDescription
LevelFault (FAULT)
Trigger ConditionPositive optical limit input remains asserted continuously for the confirmation time; reference confirmation is 10 ms, enabled only on models equipped with limit switch hardware.
Protection ActionImmediately revokes servo Enable and stops motion output; executes power-stage shutoff and brake engagement per hardware configuration.
Clearing MethodConfirm mechanical safety and clear the positive limit signal, ensure the servo is Disabled, and execute a fault reset.
TroubleshootingCheck whether the joint genuinely reached its physical positive stop, sensor mounting and active polarity, sensor supply, wiring, and noise. Avoid commanding further motion toward the positive limit during recovery.

0x0706 Negative Optical Limit Exceeded​

ItemDescription
LevelFault (FAULT)
Trigger ConditionNegative optical limit input remains asserted continuously for the confirmation time; reference confirmation is 10 ms, enabled only on models equipped with limit switch hardware.
Protection ActionImmediately revokes servo Enable and stops motion output; executes power-stage shutoff and brake engagement per hardware configuration.
Clearing MethodConfirm mechanical safety and clear the negative limit signal, ensure the servo is Disabled, and execute a fault reset.
TroubleshootingCheck whether the joint genuinely reached its physical negative stop, sensor mounting and active polarity, sensor supply, wiring, and noise. Avoid commanding further motion toward the negative limit during recovery.

0x0707 Positive Software Limit Exceeded​

ItemDescription
LevelFault (FAULT)
Trigger ConditionTarget position or feedback position reaches or exceeds the positive software travel limit; limit value and source are configured per project (some profiles reference +180°).
Protection ActionImmediately revokes servo Enable and stops motion output; executes power-stage shutoff and brake engagement per hardware configuration.
Clearing MethodVerify home zero position and mechanical safety, adjust the target position back inside the permitted range, ensure the servo is Disabled, execute a fault reset, and jog out of the limit zone at low speed.
TroubleshootingActive only when software position limits are enabled. Check home offset, multi-turn/single-turn absolute position, gear ratio, unit scaling, travel limit parameters, and commanded target position.

0x0708 Negative Software Limit Exceeded​

ItemDescription
LevelFault (FAULT)
Trigger ConditionTarget position or feedback position reaches or exceeds the negative software travel limit; limit value and source are configured per project (some profiles reference -180°).
Protection ActionImmediately revokes servo Enable and stops motion output; executes power-stage shutoff and brake engagement per hardware configuration.
Clearing MethodVerify home zero position and mechanical safety, adjust the target position back inside the permitted range, ensure the servo is Disabled, execute a fault reset, and jog out of the limit zone at low speed.
TroubleshootingActive only when software position limits are enabled. Check home offset, multi-turn/single-turn absolute position, gear ratio, unit scaling, travel limit parameters, and commanded target position.