UM0003 JxServo Studio CANFD Bridge Guide
| Item | Information |
|---|---|
| Document No. | UM0003 |
| Revision | Rev. 1.1 |
| Applicable Products | JxServo Studio, Jx CANFD Bridge |
| Recommended Tool Version | Jx CANFD Bridge GUI v2.1.0 |
| Language | English |
| Last Updated | 2026-06-25 |
Scope
This document explains how to connect a CAN FD adapter to JxServo Studio using the Jx CANFD Bridge GUI tool. Jx CANFD Bridge is a dedicated bridging utility developed by Juxie Intelligent for full-robot commissioning of humanoid robots. When a humanoid robot has already completed mechanical assembly, harness routing, or shell enclosure—making direct access to a joint module's USB debug port inconvenient—you can bridge the target module to JxServo Studio through a CAN FD adapter.
The bridge tool connects to the CAN FD bus and exposes local UDP communication ports on the PC. Once JxServo Studio connects to the bridge tool over UDP, you can continue using "数据连接" (Data Connection), "命令列表" (Command List), "常用数据" (Common Data), and "数据波形" (Data Waveform) features.
CAN FD Bus Only
Jx CANFD Bridge supports CAN FD buses ONLY. Never connect it to a non-CAN FD bus or a classical CAN 2.0 bus. Connecting to a classical CAN bus will corrupt bus traffic, cause communication errors, and potentially disrupt active control traffic on the same bus.
Waveform Usage Recommendation
The high-speed data waveform capability of JxServo Studio is designed primarily for high-speed USB links. When bridging over CAN FD, streaming large volumes of waveform data consumes significant CAN bus bandwidth and may affect real-time control communication sharing the same bus. Unless necessary, use the bridge channel only for viewing and modifying parameters; enable data waveforms or high-frequency telemetry only during fault diagnosis after confirming that waveform traffic will not impact bus control performance.
To connect a device via a direct USB cable instead, please refer to UM0001 JxServo Studio Connection and Waveform Viewing Guide.
Operational Safety
Once the CAN FD bridge is established, host commands are transmitted directly to the device over CAN FD. Before executing Enable (Servo ON), closed-loop control, calibration, or motion commands, confirm that the device is securely mounted, the motion workspace is clear, and power-off or emergency-stop measures are immediately accessible.
1. Preparation
Before starting, verify that all of the following conditions are met:
- JxServo Studio is installed and launches normally.
- The CAN FD adapter is connected to the PC, and its official vendor driver is installed.
- The CAN FD adapter is wired to the CAN FD bus of the target device.
- The target device is properly powered.
- The Module ID of the target device is known. Unless previously modified, the default ID is typically
1. - The active CAN FD bus bitrate is known. Unless previously modified, the default bitrate is typically
1M + 5M. - JxServo Studio UDP settings are confirmed. By default, local loopback IP
127.0.0.1, local port9001, and remote port9000are used.
Recommended Download: GUI Edition
The GUI edition is recommended for this workflow: Download Jx CANFD Bridge GUI v2.1.0
The GUI release package already bundles the Python runtime and all required dependencies—customer PCs do not need Python installed or any pip install commands executed. You still need to install the official vendor driver for your CAN FD adapter in advance.
Always prefer the GUI edition for normal customer operations. The legacy command-line (CLI) edition is retained only for backward compatibility or diagnostic use and is no longer offered for download on the official website.
2. Open UDP Listening in JxServo Studio
When using the CANFD bridge, it is recommended to start UDP listening in JxServo Studio first, and then launch the CANFD bridge tool.
2.1 Open the Data Connection Page
Launch JxServo Studio and open the "数据连接" (Data Connection) page. If you have already imported the recommended layout, click the "数据连接" (Data Connection) tab at the top or on the left panel.
2.2 Enter UDP Parameters and Open Connection
Under "连接方式" (Connection Mode), select "UDP连接" (UDP Connection), fill in the UDP settings, and click "打开通信连接" (Open Connection). Even though the CANFD bridge tool has not started yet, put JxServo Studio into UDP listening state first.

| No. | Action | Description |
|---|---|---|
| 1 | Open "数据连接" (Data Connection) | Configures the communication interface of JxServo Studio. |
| 2 | Select "UDP连接" (UDP Connection) | Connects to the device via the local UDP channel provided by the bridge tool. |
| 3 | Enter UDP settings | When running both the bridge tool and JxServo Studio on the same PC, set "IP 地址" (IP Address) to 127.0.0.1, "本地端口" (Local Port) to 9001, and "对侧端口" (Remote Port) to 9000. |
| 4 | Click "打开通信连接" (Open Connection) | Starts UDP listening in JxServo Studio first, waiting for the bridge tool to start and complete the link. |
Recommended values when running on the same PC:
| Parameter | Value |
|---|---|
"IP 地址" (IP Address) | 127.0.0.1 |
"本地端口" (Local Port) | 9001 |
"对侧端口" (Remote Port) | 9000 |
3. Using the GUI Bridge Tool (Recommended)
3.1 Extract and Launch the GUI Tool
Extract Jx_CANFD_Bridge_GUI_v2.1.0_20260625.zip to a local folder. Open the extracted Jx_CANFD_Bridge directory and double-click 启动CANFD桥接.vbs during normal use to launch the graphical interface.
Alternatively, you can double-click Jx_CANFD_Bridge.exe directly to start the main program. Subdirectories such as _internal, CX_V1.21, and ZLG_lib contain required runtime libraries—do not delete them or move Jx_CANFD_Bridge.exe out of the folder on its own.
3.2 Configure Bridge Parameters
In the GUI window, configure the bridge parameters according to your on-site adapter and target module:

| No. | Setting | Recommended Value / Description |
|---|---|---|
| 1 | "CANFD 设备" (CANFD Device) | Select according to your actual CAN FD adapter, such as ZLG (Zhou Ligong), Chuangxin ControlCANFD, or PCAN. |
| 2 | "CANFD 通道" (CANFD Channel) | Select "通道 0" (Channel 0) or "通道 1" (Channel 1) according to your physical wiring. |
| 3 | "CANFD 速率" (CANFD Bitrate) | Uses 1M + 5M by default; must match the current CAN FD bus bitrate of the target device. |
| 4 | "模组 ID" (Module ID) | Enter the ID of the target module to bridge, ranging from 1 to 127. |
| 5 | "启动并配对" (Start and Pair) | Click this button after verifying parameters; the tool opens the CAN FD channel and pairs with the target module. |
Keep the default UDP ports unchanged under normal circumstances:
| GUI Parameter | Default Value | Corresponding Entry in JxServo Studio |
|---|---|---|
"桥接转发端口" (Bridge Forward Port) | 9000 | "对方端口" / "对侧端口" (Remote Port): 9000 |
"Studio 接收端口" (Studio Receive Port) | 9001 | "本地端口" (Local Port): 9001 |
The "JxServoStudio UDP 填写" (JxServoStudio UDP Settings) section in the GUI displays the exact IP address, local port, and remote port to enter in JxServo Studio. If you change the ports in the GUI, update the UDP settings in JxServo Studio to match.
3.3 Start Bridging
After confirming that JxServo Studio has opened UDP listening, click "启动并配对" (Start and Pair) in the GUI. Once started successfully, keep the GUI window open throughout your session.
You do not need to close the software when switching to another Module ID:
- Modify
"模组 ID" (Module ID)and click"重新配对当前 ID" (Re-pair Current ID)to pair with the new target ID. - To stop bridging and restore the module's debug channel back to USB, click
"停止并切回 USB" (Stop and Switch Back to USB). - To clear the GUI log output, click
"清空日志" (Clear Log).
4. Verify Successful Connection
Once connected, the connection status indicator in JxServo Studio turns green and the "设备列表" (Device List) displays the recognized device details. The "常用数量" (Common Data) panel on the right automatically displays baseline telemetry including bus current, bus voltage, joint velocity, joint angle, motor velocity, live Iq current, MOSFET temperature, motor temperature, and force/torque sensor readings.

You can confirm normal CAN FD bridge communication by checking the following indicators:
- The
"连接状态" (Connection Status)indicator turns green. - The
"设备列表" (Device List)displays the device name, device address, hardware version, firmware version, protocol version, and bootloader (BL) version. - Log messages indicating successful device info retrieval and command list retrieval appear in the bottom-left log panel.
- Basic device telemetry is live-updated in the right-side common data panel.
- Clicking
"获取命令列表" (Get Command List)at the bottom populates the command panel with commands supported by the connected device.
To view real-time curves, switch to the "数据波形" (Data Waveform) page and add desired variables following UM0001 Section 3.5.
5. Command-Line Edition (Optional)
The command-line (CLI) edition is retained solely for legacy compatibility or diagnostics. Prefer the GUI edition for normal customer operations; the legacy CLI package is no longer available for download on the official website.
If you already hold an earlier CLI release archive, follow these steps:
- Extract the legacy CLI release archive.
- First open UDP listening in JxServo Studio as described in Section 2.
- Double-click
启动CANFD桥接.bat. - Follow the terminal prompts to select the CANFD device, CANFD channel, CANFD bitrate, Module ID, bridge forward port, and Studio receive port.
- Once the terminal displays
"UDP 桥接已启动" (UDP Bridge Started), keep the command prompt window open. - When finished, press
Ctrl+Cin the command prompt window and wait for the tool to switch the module channel back to USB before closing the window.
Default values in the CLI edition:
| Setting | Default Value |
|---|---|
"CANFD 通道" (CANFD Channel) | 0 |
"CANFD 速率" (CANFD Bitrate) | 1M + 5M |
"模组 ID" (Module ID) | 1 |
"桥接转发端口" (Bridge Forward Port) | 9000 |
"Studio 接收端口" (Studio Receive Port) | 9001 |
6. Ending a Bridge Session
When finishing your debugging session, close the connection in the following order:
- Click
"关闭通信连接" (Close Connection)in JxServo Studio. - In the GUI edition, click
"停止并切回 USB" (Stop and Switch Back to USB); in the CLI edition, pressCtrl+Cinside the terminal window. - Wait until the bridge tool completes its cleanup procedure before closing the bridge tool window.
If you subsequently want to reconnect via a direct USB cable, exit the bridge tool cleanly first before reconnecting in JxServo Studio.
7. Troubleshooting
7.1 Connection Status in JxServo Studio Does Not Turn Green
Check whether the bridge tool is still running, and verify that the bridge port parameters match the UDP settings in JxServo Studio. By default, JxServo Studio uses IP address 127.0.0.1, local port 9001, and remote port 9000.
7.2 Unable to Open the CAN FD Adapter
Verify that the official CAN FD adapter driver is installed, the adapter is plugged into the PC, and the selected device type and channel number are correct. If the same adapter is currently occupied by ZCANPRO, PCAN-View, or another CAN FD utility, close that software first before starting the bridge tool.
7.3 Bridge Starts, but Device Information Cannot Be Read
Inspect CAN FD bus wiring, termination resistors, device power supply, Module ID, and CAN FD bitrate. The Module ID configured in the bridge tool must match the target device, and the CAN FD bitrate must match the active bus bitrate of the device.
7.4 UDP Reset Notice or WinError 10054
The GUI edition automatically ignores transient Windows UDP socket resets and keeps running. If you see this notice, verify that UDP connection listening is open in JxServo Studio and that the local and remote ports are configured properly.
If the legacy CLI edition exits with [WinError 10054] 远程主机强迫关闭了一个现有的连接 (An existing connection was forcibly closed by the remote host), first open the "数据连接" (Data Connection) page in JxServo Studio, select "UDP连接" (UDP Connection), set IP address 127.0.0.1, local port 9001, and remote port 9000, click "打开通信连接" (Open Connection), and then restart the CLI bridge tool.
7.5 Port Already in Use or Abnormal Communication
The default UDP ports are 9000 and 9001. If either port is occupied by another process, change to unused port numbers in the bridge tool and update both the local port and remote port accordingly in JxServo Studio's UDP settings. If Windows Firewall prompts for network access permission on first launch, allow local UDP communication.